ZUP20-10/U TDK Corporation, ZUP20-10/U Datasheet

PWR SUP BENCH PROG 0-20V 200W

ZUP20-10/U

Manufacturer Part Number
ZUP20-10/U
Description
PWR SUP BENCH PROG 0-20V 200W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP20-10/U

Load Regulation
0.01%
Voltage - Output
0 ~ 20V
Number Of Outputs
1
Power (watts)
200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 20 VDC @ 10A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
200W
Operating Temperature
0°C ~ 50°C
Efficiency
78%
Approvals
CE, EN, UL
Line Regulation
0.01%
Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
20V
Output Current
10A
Power Rating
200W
Input Voltage
85V AC To 265V AC
Length
350mm
Width
70mm
Accuracy
0.02% + 12 mV
Brand/series
ZUP
Current, Output
10 A
Display Type
Digital Meter
Power, Output
200 W
Power, Rating
200 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
20 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1673
Q1142280
ZUP20-10/U
ZUP2010/U
S p e c i f i c a t i o n s
ITEMS
Load Regulation
Line Regulation
Recovery Time
Temperature Coefficient
Temperature Drift(2)
Up programming response time
Down prog. resp. time (CV)
Down prog. resp. time (CV)
Load Regulation
Line Regulation
Temperature Coefficient
Temperature Drift(2)
Prog Voltage resolution
Prog Voltage accuracy
Prog Current resolution
Prog Current accuracy
Overvoltage Shutdown
Thermal Protection
Display - Voltage
Display - Current
Display - Status
Remote On/Off
Output Good
Voltage & Current Programming
Remote Sense
Communication Interface
Series & Parallel Operation
AC Input Voltage range
Inrush Current (100/200VAC) (3)
Hold Up Time (Typ) at 100VAC
Power Factor Correction
Temperature Range
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration & Shock (non-op.)
Safety Agency Approvals
Conducted & Radiated EMI
Warranty
Notes:
(1)
(2)
(3)
Recovery to within +/-50mV after load change of 50-100%
Over 8 hour period following 30 minute warm up time
25°C ambient (cold start)
MODELS
(1)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
Cond.
Zero
Full
CC
CC
CC
CC
CV
CV
CV
CV
CV
CV
ms
V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
.02%+5mV
3 digits (6, 20, 36, 60, 80V models), 3.5 digits (10, 120V models). Accuracy 0.2% ± 2 digits
Vibration:10-55Hz(1 min.) 2G constant X, Y, Z, when correctly mounted; Shock: <20G
250ms
0 - 7.5
ZUP6
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
1ms
0.01% + 5mA on 200W and 400W models, 0.07% + 10mA on 800W models
0.01% + 2mA on 200W and 400W models, 0.01% + 5mA on 800W models
Series: Up to two units; Parallel: Up to five units in master-slave configuration
0.02% + 5mA, 200W and 400W models, 0.05% + 10mA 800W models
15/30A, 200W models, 15A, 400W models, 30A, 800W models
100ppm/°C from rated current after 30 minute warm up time
1mV + 0.005% over 85 - 132 or 170 - 265VAC line change
.02%+8mV
50 - 60ms
EN55022-B conducted, A radiated, FCC Class B conducted,
3 digits, (3.5 digits 132A model). Accuracy 0.5% ± 3 digits
350ms
ZUP10
0.5ms
0 - 13
CV / CC, Alarm, Foldback, Local/Remote, On/Off
Operating: 30 - 90% RH, Storage 10 - 95%RH
Complies with EN61000-3 Class A (0.99 typ)
Operating: 0 - 50°C; Storage: -20 to +70°C
2mV + 0.005% over 0 - 100% load change
By either Voltage (0-4V) or Resistance (0-4k)
RS232 & RS485 standard, IEEE488 optional
A radiated, VCCI-2 conducted, -1 radiated
Up to 0.5V compensation per output cable
30ppm/°C following 30 minute warm up
Better than 0.028% of rated voltage
ZUP Series
Zero up programmable power supplies
.02%+12mV .02%+20mV .02%+35mV .02%+50mV .02%+70mV
Better than 0.03% of rated voltage
UL3111-1, EN61010-1, CE Mark
0.01% + 2mV change in output
TTL signal or dry contact relay
ZUP20
400ms
0 - 24
Over temperature protected
>100M at 25°C & 70%RH
Constant Voltage / Constant Current
Last Setting Memory
Digital Meters
Built-in RS232 & RS485 Interface w/ GPIB optional
Bench or Rack Mount
Embedded Microprocessor Controller
Voltage up to 120V, Current up to 132A
50ms (70ms ZUP60-14)
85-265VAC (47-63Hz)
Open Collector
0.4% + 40mA
Internal fan
Three Years
500ms
20
ZUP36
0 - 40
0.2ms
750ms
ZUP60
0 - 66
ZUP80
600ms
0 - 88
80ms
ZUP120
0 - 132
120ms
800ms
85

Related parts for ZUP20-10/U

ZUP20-10/U Summary of contents

Page 1

... Built-in RS232 & RS485 Interface w/ GPIB optional Bench or Rack Mount Embedded Microprocessor Controller Voltage up to 120V, Current up to 132A ZUP6 ZUP10 ZUP20 2mV + 0.005% over 0 - 100% load change 1mV + 0.005% over 85 - 132 or 170 - 265VAC line change 1ms 0.5ms 30ppm/°C following 30 minute warm up ...

Page 2

... Range Range ZUP6-33/U 0-6V 0-33 ZUP6-66/U 0-6V 0-66 ZUP6-132/U 0-6V 0-132 ZUP10-20/U 0-10 0-20 ZUP10-40/U 0-10 0-40 ZUP10-80/U 0-10 0-80 ZUP20-10/U 0-20 0-10 ZUP20-20/U 0-20 0-20 ZUP20-40/U 0-20 0-40 ZUP36-6/U 0-36 0-6 ZUP36-12/U 0-36 0-12 ZUP36-24/U 0-36 0-24 ZUP60-3.5/U 0-60 0-3.5 ...

Related keywords