ZUP60-7/U TDK Corporation, ZUP60-7/U Datasheet - Page 47

PWR SUP BENCH PROG 0-60V 420W

ZUP60-7/U

Manufacturer Part Number
ZUP60-7/U
Description
PWR SUP BENCH PROG 0-60V 420W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP60-7/U

Load Regulation
0.01%
Voltage - Output
0 ~ 60V
Number Of Outputs
1
Power (watts)
420W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 60 VDC @ 7A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
420W
Operating Temperature
0°C ~ 50°C
Efficiency
84%
Approvals
CE, EN, UL
Line Regulation
0.01%
Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
60V
Output Current
7A
Power Rating
420W
Input Voltage
85V AC To 265V AC
Length
350mm
Width
70mm
Accuracy
0.02% + 35 mV
Brand/series
ZUP
Current, Output
7 A
Display Type
Digital Meter
Power, Output
420 W
Power, Rating
420 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
60 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1681
ZUP607/U
5
1
Fig. 5-7: RS485 cable with
5.4
DB-9 female connector.
5.4.1 Introduction
For operation environments that require high noise immunity or long distance communication, it is
recommended to use the built-in RS485 interface. The RS485 interface is accessible through the
rear panel In/Out jacks in a similar way to the RS232. The communication is a four-wire type. Refer to
par. 5-6 for detailed explanation. Up to 31 ZUP units can be connected to the RS485 control as shown
in Fig. 5-6.
Fig. 5-6: Linking ZUP units to RS485 control.
5.4.2 RS485 cable ( PC to ZUP ) - NC402
5.4.3 Linking power supplies
Power supplies are linked in the same way as described in par. 5.3.4.
5.5
The ZUP command set is divided into four categories as follows: 1. Initialization Control
The commands structure, syntax, and registers definition are described in this paragraph as listed
above.
REMOTE PROGRAMMING VIA RS485
ZUP SERIES COMMAND SET DESCRIPTION
RS485
ZUP (1)
1000m max.
HOUSING
RS485
PIN NO.
DB-9 CONNECTOR
9
8
1
5
4
ZUP (2)
SHIELD
TXD
TXD
SG
RXD
RXD
NAME
-
+
-
+
2. ID Control
3. Output Control
4. Status Control
RS485
HOUSING
PIN NO.
6
8
5
2
4
8 PIN CONNECTOR
NAME
SHIELD
RXD
RXD
SG
TXD
TXD
ZUP (31)
+
+
-
-
REMARKS
TWISTED
TWISTED
PAIR
PAIR
1
8

Related parts for ZUP60-7/U