ZUP20-20/U TDK Corporation, ZUP20-20/U Datasheet - Page 42

PWR SUP BENCH PROG 0-20V 400W

ZUP20-20/U

Manufacturer Part Number
ZUP20-20/U
Description
PWR SUP BENCH PROG 0-20V 400W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Enclosedr
Datasheets

Specifications of ZUP20-20/U

Number Of Outputs
1
Efficiency
83%
Voltage - Output
0 ~ 20V
Power (watts)
400W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 20 VDC @ 20A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
400W
Operating Temperature
0°C ~ 50°C
Approvals
CE, EN, UL
Line Regulation
0.01%
Load Regulation
0.01%
Output Current (max)
20A
Input Voltage
85 to 265V
Output Power (max)
400W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Accuracy
0.02% + 12 mV
Brand/series
ZUP
Current, Output
20 A
Display Type
Digital Meter
Power, Output
400 W
Power, Rating
400 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
20 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1674
ZUP2020/U
3. Series connection for bipolar output voltage:
the current limits of each power supply to the maximum that the load can handle without damage. It is
recommended to connect diodes in parallel to each unit output to prevent reverse voltage during start-
up condition or in case one of the units shuts down. Each diode should be rated to at least the power
supply’s output current. Refer to Fig. 4-14 for this operating mode.
3.1 General: At this operation mode, two units are configured as a bipolar voltage/current source. Set
3.2 Remote programming at series operation for bipolar output voltage:
1. Programming by external voltage; The analog programming circuits of the ZUP power supply
2. Programming by external resistor: Programming by external resistor is possible. Refer to
3. Programming via the communication port (RS232/RS485): The communication port is isolated
are referenced to the - Sense potential. Therefore, the circuits used to control each unit must
be separated and floated from each other.
Fig. 4-5 and Fig. 4-6 for details.
from the output voltage, therefore the serialy connected power supplies can be chained using
the Remote-In and Remote-Out connectors.
Fig. 4-14: Series connection for bipolar output
SUPPLY
SUPPLY
POWER
POWER
- LS
- LS
+LS
+LS
- S
- S
+S
+S
+
_
+
_
COM
+
_
LOAD