ZUP60-14/U TDK Corporation, ZUP60-14/U Datasheet - Page 37

PWR SUP BENCH PROG 0-60V 840W

ZUP60-14/U

Manufacturer Part Number
ZUP60-14/U
Description
PWR SUP BENCH PROG 0-60V 840W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP60-14/U

Load Regulation
0.07%
Voltage - Output
0 ~ 60V
Number Of Outputs
1
Power (watts)
840W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 60 VDC @ 14A
Size / Dimension
13.78" L x 5.51" W x 4.88" H (350mm x 140mm x 124mm)
Power (watts) - Rated
840W
Operating Temperature
0°C ~ 50°C
Efficiency
84%
Approvals
CE, EN, UL
Line Regulation
0.01%
Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
60V
Output Current
14A
Power Rating
840W
Input Voltage
85V AC To 265V AC
Length
350mm
Width
140mm
Accuracy
0.02% + 35 mV
Brand/series
ZUP
Current, Output
14 A
Display Type
Digital Meter
Power, Output
840 W
Power, Rating
840 W (Max.)
Regulation, Line
0.01% + 5 mA⁄1 mV + 0.005%
Regulation, Load
0.07% + 7 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
60 mV @ 20 MHz BW
Voltage, Output
60 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1679
ZUP6014/U
4. OUTPUT VOLTAGE PROGRAMMING BY EXTERNAL RESISTOR
Fig 4-5 shows a typical set-up for programming the output voltage. A variable programming resistor,
0~4Kohm produces a proportional output voltage from zero to full scale. In order to set the low limit, a
series resistor can be connected to the programming resistor. For example; a 1kohm series resistor will
set the lower limit to 25% of full scale. In order to set the upper limit, a resistor can be connected in
parallel to the programming resistor. The resultant programming resistance of the series/parallel
resistors must be between 0 and 4Kohm.
Fig. 4-5:
Constant voltage resistive programming.
Fig. 4-6:
Constant current resistive programming.
5.OUTPUT CURRENT PROGRAMMING BY EXTERNAL RESISTOR
Fig 4-6 shows the set-up for constant current resistive programming. The explanation given for
constant voltage resistive programming also applies for constant current.
Resistive programming is possible for local and remote sensing.
sets lower
sets lower
Optional
Optional
limit
limit
programming resistor
programming resistor
0~4K
0~4K
NOTE
sets upper limit
sets upper limit
Optional
Optional
VCVP
VCCP
RCCP
COM
VCVP
VCCP
RCCP
External control connector
External control connector
- S
+S
COM
P
(ZUP rear panel view)
(ZUP rear panel view)
- S
+S
P
14
14
2
2
13
1
13
1
Output Good
Output Good
On/Off
VRFV
VRFI
RCVP
On/Off
VRFV
VRFI
RCVP
- LS
+LS
- LS
+LS