ZUP10-80/U TDK Corporation, ZUP10-80/U Datasheet - Page 47

PWR SUP BENCH PROG 0-10V 800W

ZUP10-80/U

Manufacturer Part Number
ZUP10-80/U
Description
PWR SUP BENCH PROG 0-10V 800W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP10-80/U

Voltage - Output
0 ~ 10V
Number Of Outputs
1
Power (watts)
800W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 10 VDC @ 80A
Size / Dimension
13.78" L x 5.51" W x 4.88" H (350mm x 140mm x 124mm)
Power (watts) - Rated
800W
Operating Temperature
0°C ~ 50°C
Efficiency
81%
Approvals
CE, EN, UL
Line Regulation
0.01%
Load Regulation
0.07%
Accuracy
0.02% + 8 mV
Brand/series
ZUP
Current, Output
80 A
Display Type
Digital Meter
Power, Output
800 W
Power, Rating
800 W (Max.)
Regulation, Line
0.01% + 5 mA⁄1 mV + 0.005%
Regulation, Load
0.07% + 7 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
90 mV @ 20 MHz BW
Voltage, Output
10 VDC
Voltage, Ripple
8 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1670
ZUP1080/U
5
1
Fig. 5-7: RS485 cable with
5.4
DB-9 female connector.
5.4.1 Introduction
For operation environments that require high noise immunity or long distance communication, it is
recommended to use the built-in RS485 interface. The RS485 interface is accessible through the
rear panel In/Out jacks in a similar way to the RS232. The communication is a four-wire type. Refer to
par. 5-6 for detailed explanation. Up to 31 ZUP units can be connected to the RS485 control as shown
in Fig. 5-6.
Fig. 5-6: Linking ZUP units to RS485 control.
5.4.2 RS485 cable ( PC to ZUP ) - NC402
5.4.3 Linking power supplies
Power supplies are linked in the same way as described in par. 5.3.4.
5.5
The ZUP command set is divided into four categories as follows: 1. Initialization Control
The commands structure, syntax, and registers definition are described in this paragraph as listed
above.
REMOTE PROGRAMMING VIA RS485
ZUP SERIES COMMAND SET DESCRIPTION
RS485
ZUP (1)
1000m max.
HOUSING
RS485
PIN NO.
DB-9 CONNECTOR
9
8
1
5
4
ZUP (2)
SHIELD
TXD
TXD
SG
RXD
RXD
NAME
-
+
-
+
2. ID Control
3. Output Control
4. Status Control
RS485
HOUSING
PIN NO.
6
8
5
2
4
8 PIN CONNECTOR
NAME
SHIELD
RXD
RXD
SG
TXD
TXD
ZUP (31)
+
+
-
-
REMARKS
TWISTED
TWISTED
PAIR
PAIR
1
8

Related parts for ZUP10-80/U