MAP110-4300 POWER ONE, MAP110-4300 Datasheet
MAP110-4300
Specifications of MAP110-4300
Related parts for MAP110-4300
MAP110-4300 Summary of contents
Page 1
... Description Power-One’s MAP110 Series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. Wide dynamic output current and fixed-frequency operation simplifies system level operation. The MAP110 series is configured to an international standard footprint ...
Page 2
... Fixed +15V Fixed +12V 11.55V to 12.45V +24V Fixed MAP110-4200 -12V Fixed +5V Fixed +3.3V 3.2V to 3.4V +5V Fixed MAP110-4300 -12V Fixed (Note 3) +12V Fixed +3.3V 3.2V to 3.4V +5V Fixed MAP110-4305 -5V Fixed (Note 3) +12V Fixed NOTES: 1) Peak loads up to 110 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 watts. ...
Page 3
... NOTES: 1) Minimum load is required only to meet the regulation limits of V3 and V4 and V4 are unused, no minimum load is necessary. 2) The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300. MCD10142 Rev. 1.0, 27-Jan-10 MAP110 AC-DC Series Data Sheet MAP110-1005 MAP110-1012 MAP110-1024 MAP110-4200 MAP110-4300 All other models. Page MIN NOM MAX UNITS 65 ...
Page 4
... Warning time increases at reduced load levels. Thermal Add ‘T’ suffix to model number. Initiates shut-down in the event of an overtemperature Shutdown condition. Automatic recovery. MCD10142 Rev. 1.0, 27-Jan-10 MAP110 AC-DC Series Data Sheet At 100% load: At 50% load: Page MIN NOM ...
Page 5
... Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10142 Rev. 1.0, 27-Jan-10 MAP110 AC-DC Series Data Sheet OVERALL WEIGHT: 1.3 lb (0.59 kg) Page NOTE 1 ...