FXA350012A ICC/Elpac Power Syst, FXA350012A Datasheet

PWR SUPP SW-MODE 12V 20A 350W

FXA350012A

Manufacturer Part Number
FXA350012A
Description
PWR SUPP SW-MODE 12V 20A 350W
Manufacturer
ICC/Elpac Power Syst
Series
FXA 350r
Datasheet

Specifications of FXA350012A

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
350W
Applications
Medical
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 20A
Size / Dimension
8" L x 5" W x 1.5" H (203.2mm x 127mm x 38.1mm)
Power (watts) - Rated
350W
Operating Temperature
0°C ~ 70°C
Efficiency
88%
Approvals
CAN/CSA, CB, CE, cTUVus, UL
Line Regulation
±5%
Load Regulation
±5%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
EPS453
A
1-888-357-2280
saleselpac@iccus.com
www.iccus.com
+44.1383.432920
saleseurope@iccus.com
TECHnICAL SUPPORT
WORLDWIDE
EUROPE
Notes
**Ripple and noise measured with 20MHz bandwidth; 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor.
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Zero Load
Power Consumption
Touch Current/
Leakage Current (typical)
Input
*visit www.iccus.com for complete details
5-YEAR LIMITED WARRAnTY*
85 – 264VAC
100 – 240VAC Nominal
47 – 63Hz
<5A rms
<37A at 230VAC cold start
>0.98
0.75W
<200µA @ 132VAC @ 60Hz
<300µA @ 264VAC @ 60Hz
Output Voltage
Total Regulation
Minimum Load
Start-Up Delay
Hold-Up Time
Ripple & Noise
Over Voltage Protection
Over Temperature Protection
Over Current Protection
Short Circuit Protection
Output
FXA350 Series
Switch Mode Power Supply
High Efficiency: Level V
Wide Range AC Input
Power Factor Correction
+5V Standby & Fan Power
Fully regulated DC output
EISA and CEC Compliant
Grounded Output
ITE and Medical Grade Approval
See Table
+/-5%
No minimum load required
<1s
>24ms at any input voltage
<1% pk-pk **
110 – 135%
Active - Recoverable; plus
Passive - Non Recoverable
120 – 180%
Shutdown, auto-restart
(hiccup mode)
350 Watts

Related parts for FXA350012A

FXA350012A Summary of contents

Page 1

TECHnICAL SUPPORT WORLDWIDE 1-888-357-2280 saleselpac@iccus.com www.iccus.com EUROPE +44.1383.432920 saleseurope@iccus.com Input Input Voltage Input Frequency Input Current Inrush Current Power Factor Zero Load Power Consumption Touch Current/ Leakage Current (typical) Notes *visit www.iccus.com for complete details **Ripple and noise measured with ...

Page 2

... Model Number Output Voltage FXA350012A 12.0V FXA350015A 15.0V FXA350024A 24.0V FXA350028A 28.0V FXA350048A 48.0V Notes 1) With convection cooling. Peak load (350W) lasting up to 500ms with a maximum 10% duty cycle. 2) Sustained output current with minimum 100 LFM. 3) Output present when ever AC input is applied 4) Output self adjusting dependant on ambient temperature. Range 13V over 25˚ ...

Page 3

Input Configuration (H1) Connection on JITE p/n BTB555-10-03 Barrier Strip, M3 screws Power Supply Body Pin 1 AC Line Pin 2 AC Neutral Pin 3 Gnd Signal Configuration (H2) Connector: AMP P/N 640456-8 or equivalent Mating AMP p/n 640440-8 or ...

Related keywords