QPD-60-24 QUALTEK ELECTRONICS, QPD-60-24 Datasheet

no-image

QPD-60-24

Manufacturer Part Number
QPD-60-24
Description
POWER SUPPLY ENCLOSED 24V 2.5A
Manufacturer
QUALTEK ELECTRONICS
Series
QPD-60r
Datasheet

Specifications of QPD-60-24

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
60W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
88 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 2.5A
Size / Dimension
5.08" L x 3.86" W x 1.50" H (129mm x 98mm x 38mm)
Power (watts) - Rated
60W
Operating Temperature
-20°C ~ 70°C
Efficiency
80%
Approvals
CE, cUL, EN, UL
Line Regulation
±0.5%
Load Regulation
±2%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
60Watts Single Output
Model
Output Characteristics
Input Characteristics
DC Output
Rated Current
Current Range
Ripple and
Noise
Voltage ADJ. Range
Voltage Accuracy
Line Regulation
Load Regulation
Set-up Time
Hold-up Time
Temperature Coefficient
Overshoot and Undershoot
Voltage Range
Frequency Range
Efficiency (Typical)
AC Current (max)
Inrush Current (Typical)
Leakage Current
Protection
Over Load (OLP)
Over Voltage (OVP)
Short Circuit (SCP)
Environmental Characteristics
Operating Amb. Temp. & Hum
Storage Temp. & Hum
Safety Standards
Withstand Voltage
Isolation Resistance
EMI Conduction & Radiation
EMS Immunity
General Characteristics
MTBF (MIL-HDBK-217F)
Dimension (LxWxH)
Packing
Cooling Method
0~55°C
-10~0°C
QPD-60-5
5V
12A
0~12A
50mV
100mV
4.2V-5.8V
±2.0%
±0.5%
±2.0%
<2.0s (115VAC input, full load); <1.0s (230VAC input, full load)
>10ms (115VAC input, full load); >20ms (230VAC input, full load)
±0.03%/°C
<5.0%
105%~150% of rated output current, hiccup mode, auto recovery
120%~150% of rated output voltage, shut down, re-power on to recover (5V)
110%~133% of rated output voltage, shut down, re-power on to recover (12V)
110%~140% of rated output voltage, shut down, re-power on to recover (15V, 24V)
110%~125% of rated output voltage, shut down, re-power on to recover (48V)
Long-term mode, auto recovery
-20°C~70°C; 20%~90% RH Non-Condensing
-40°C~85°C: 10%-95% RH Non-Condensing
UL60950-1; EN60950-1: 2006
Primary-Secondary: 3.0KVAC;≤10mA. Primary-PG: 1.5KVAC;≤10mA. Secondary-PG: 0.5KVDC;≤10mA
≥100M ohms
Compliance to EN55022(CISPR22) Class B
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, light industry level, criteria A
More than 100,000Hrs (25°C, Full load)
129x98x38mm
30PCS/CTN. G.W: 14.2kgs
Cooling by free air convection
88VAC~264VAC
47Hz-63Hz
83%
1.6A
20A@115VAC Cold start 40A@230VAC Cold start
<0.25mA@115VAC <3.5mA@230VAC
80%
1.6A
QPD-60-12
12V
5A
0~5A
120mV
120mV
10.8V-13.2V
±2.0%
±0.5%
±2.0%
Electronics Corporation
QPD-60-15
15V
4A
0~4A
120mV
120mV
13.5V-16.5V
±2.0%
±0.5%
±2.0%
80%
1.5A
Features:
Universal AC input/ Full range
Wide Operating Ambient Temperature (-20°C~70°C)
High Efficiency, and High Reliability
Output Protections: OLP/OVP/SCP
All using 105°C long life electrolytic capacitors.
100% full load burn-in test
24V
2.5A
0~2.5A
120mV
120mV
21.5V-25.8V
±2.0%
±0.5%
±2.0%
QPD-60-24
80%
1.5A
P C
P
QPD-60 Series
QPD-60-48
48V
1.25A
0~1.25A
240mV
240mV
45V-52V
±2.0%
±0.5%
±2.0%
83%
1.45A
Page 1 of 2

Related parts for QPD-60-24

QPD-60-24 Summary of contents

Page 1

... Universal AC input/ Full range Wide Operating Ambient Temperature (-20°C~70°C) High Efficiency, and High Reliability Output Protections: OLP/OVP/SCP All using 105°C long life electrolytic capacitors. 100% full load burn-in test QPD-60-12 QPD-60-15 QPD-60-24 12V 15V 24V 5A 4A 2.5A 0~5A 0~4A 0~2 ...