SWT40-5FF TDK Corporation, SWT40-5FF Datasheet

PWR SUP 40W +5 +15 -15V TRIPLE

SWT40-5FF

Manufacturer Part Number
SWT40-5FF
Description
PWR SUP 40W +5 +15 -15V TRIPLE
Manufacturer
TDK Corporation
Series
SWT40r
Datasheets

Specifications of SWT40-5FF

Voltage - Output
5V, ±15V
Number Of Outputs
3
Power (watts)
40W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 3A
2nd Output
15 VDC @ 1.5A
3rd Output
-15 VDC @ 300mA
Size / Dimension
5" L x 3" W x 1.4" H (127mm x 76.2mm x 35.6mm)
Power (watts) - Rated
40W
Operating Temperature
0°C ~ 50°C
Efficiency
70%
Approvals
CSA, DENAN, EN, UL
Line Regulation
1%, 2%
Load Regulation
2%, 4%
4th Output
-
Other names
285-1073
SWT405FF
10 OUTPUT VOLTAGE
11 MAX. RIPPLE & NOISE
12 MAX. LINE REGULATION
13 MAX. LOAD REGULATION
14 MAX. TEMPERATURE DRIFT
15 OVER CURRENT PROTECTION ( * 7)
16 OVER VOLTAGE PROTECTION ( * 8)
17 HOLD - UP TIME (TYP)
18 OPERATING TEMPERATURE
19 OPERATING HUMIDITY
20 STORAGE TEMPERATURE
21 STORAGE HUMIDITY
22 COOLING
23 EMI
24 WITHSTAND VOLTAGE
25 ISOLATION RESISTANCE
26 VIBRATION
27 SHOCK
28 OUTPUT GROUNDING
29 SAFETY
30 WEIGHT
31 SIZE (W*D*H)
1 NOMINAL OUTPUT VOLTAGE
2 MIN. OUTPUT CURRENT
3 MAX. OUTPUT CURRENT
4 PEAK OUTPUT CURRENT
5 MAX. OUTPUT POWER (PEAK)
6 EFFICIENCY (TYP)
7 INPUT VOLTAGE RANGE
8 INPUT CURRENT (TYP)
9 INRUSH CURRENT (TYP)
Fig. A
CA702-01-01E
*10. Peak current operation is less than 10 sec. with duty factor less than 30%. In addition, it does not has to satisfy the total
CN2
NOTES:
ITEMS
*1. At 100VAC, 200VAC and MAX. OUTPUT POWER (Convection cooling), Ta=25°C.
*2. For cases where conformance to various safety specs (UL,CSA, EN) are required to be described as
*3. Please refer to Fig A for measurement determination of line & load regulation and output ripple voltage.
*4. From 85~132VAC / 170~265VAC, constant load.
*5. From Min. load - Full load ( Maximum power ), constant input voltage.
*6. From 0°C ~ +50°C, constant input voltage and load.
*7. Current limiting with automatic recovery. Avoid to operate over load or dead short for more than 30 seconds.
*8. Over voltage clamping by zener diode.
*9. At standard mounting method, Fig B.
L: 150mm AWG#18
C1,C3,C5: Film Cap 0.1µF
C2,C4,C6: Elec. Cap 100µF
Bandwidth of scope: 100MHz
100~120VAC, 200~240VAC, 50/60 Hz on name plate.
(Measure with JEITA RC-9131 probe)
regulation specification.
GND
GND
+5V
+5V
+V
-V
L
MODEL
C6
C4
( *10)
( * 1)
( * 2)
( * 1)
( * 3)
( *3,4)
( *3,5)
( *3,6)
( * 1)
( * 9)
SWT40 SPECIFICATIONS
Measurement point for
Vo Load / Line
regulation
C2
C3
C5
m/m
inch
W
V
A
A
A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
C1
Measurement point for
V ripple
I/P-O/P:3kVAC(20mA),I/P-FG:2.5kVAC(20mA),O/P-FG:500VAC(100mA) for 1min
CH1
0.2
4.5
A
A
A
+5
Shipment condition: CH1: ±1%, CH2(+12V): ±3%,CH2(+15V): ±5%, CH3: ±5%
3
10 - 55Hz Amplitude ( sweep 1min ) Less than 19.6m/s
SWT40-522
42.6(54.6)
More than 100M at Ta=25°C and 70%RH, Output - FG 500VDC
CH2
+12
0.3
2
3
Convection cooling 0~50°C: 100% load; 60°C: 70% load
3.00 x 5.00 x 1.40 (2.55 x 4.55 mounting hole
AC85~265V (Continuously), 47 ~ 63Hz / 110~340VDC
15A / 100VAC, 30A / 200VAC (cold start, Ta=25°C)
Conform to UL1950, CSA950, EN60950, DENTORI
±5V: 120mV;
Automatic recovery,
CH3
1.11A(Vin=100VAC) / 0.55A(Vin=200VAC)
0.3
-12
Conform to FCC-B, VCCI-2, EN55022B
0
-
All channels common ground (2 terminals)
CH1:1% , CH2: 2% , CH3: 1%
CH1: 2%, CH2: 4% , CH3: 2%
CH1 +5V fixed, CH2.3 fixed
CH1
0.2
4.5
+5
3
17ms (Input 100 VAC)
Less than 196.1m/s
6V ~
76.2 x 127.0 x 35.6
Convection cooling
SWT40-525
-20°C ~ +85°C
40.5(51.6)
±12V: 150mV; ±15V: 150 mV
30%~90%RH
10%~95%RH
0.04%/°C
CH2
+12
0.3
2
3
280g
70%
(CH1 only)
O.C.P point : 140% ~
CH3
0.3
-5
0
-
2
Fig. B
Component side
CH1
0.2
4.5
DENSEI-LAMBDA
+5
3
2
X ,Y ,Z 1Hr each
3.5mm)
SWT40-5FF
CH2
42(51.6)
+15
0.3
1.5
2.4
CH3
0.3
-15
0
-

Related parts for SWT40-5FF

SWT40-5FF Summary of contents

Page 1

... All channels common ground (2 terminals) - Conform to UL1950, CSA950, EN60950, DENTORI - m/m inch 3.00 x 5.00 x 1.40 (2.55 x 4.55 mounting hole Measurement point for V ripple Measurement point for Vo Load / Line regulation DENSEI-LAMBDA SWT40-525 SWT40-5FF CH2 CH3 CH1 CH2 +5 + +15 0.2 0.3 0 0.2 0 0.3 3 1.5 4.5 ...

Page 2

SWT 40 OUTPUT DERATING CA702-01-03A Ta (°C) MOUNTING : A MOUNTING : B MOUNTING : C MOUNTING : D 0 100 20 100 40 100 50 100 60 70 100 MOUNTING : B ...

Related keywords