no-image

RTW281R8

Manufacturer Part Number
RTW281R8
Description
POWER SUPPLY IND 28V 1.8A 50.4W
Manufacturer
TDK Corporation
Series
RTWr
Datasheets

Specifications of RTW281R8

Voltage - Output
28V
Number Of Outputs
1
Power (watts)
50W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
28 VDC @ 1.8A
Size / Dimension
4.88" L x 0.87" W x 3.23" H (124mm x 22.1mm x 82mm)
Power (watts) - Rated
50.4W
Operating Temperature
-10°C ~ 71°C
Efficiency
85%
Approvals
CE, CSA, cUL, EN, UL
Line Regulation
0.2%
Load Regulation
0.4%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
RTW28-1R8
Characteristics, Functions, and Applications
BLOCK DIAGRAM
COMMON SPECIFICATIONS
Temperature and humidity
Temperature range
Humidity range
Vibration and shock
Vibration
Shock
Withstand voltage and insulation resistance
Withstand voltage
Insulation resistance
• All specifications are subject to change without notice.
AC input
N
L
Input
filter
circuit
Operating(°C)
Operating available(°C)
Storage(°C)
Operating(%)RH
Storage(%)RH
5 to 10Hz
10 to 200Hz
Acceleration
Pulse duration
Input terminal to ground(G)
Input terminal to output terminal
Output terminal to ground(G)
Input terminal to ground(G)
Input terminal to output terminal
Output terminal to ground(G)
Input
rectifier
circuit
Surge
current
limiting
circuit
PFC control
circuit
Boost-up
circuit
–10 to +71
–20 to –10
–30 to +75
10 to 95[Maximum wet-bulb temperature: 35°C, without dewing]
All amplitude 10mm[3 directions, each 1h, Sweep time 10min]
Acceleration 19.6m/s
50W: 392m/s
100W588m/s
100W: 196m/s
100W:
150, 300W: 588m/s
11±5ms
Eac: 2.0kV, 1min[Normal temperature, normal humidity, cutout current 10mA]
Eac: 3.0kV, 1min[Normal temperature, normal humidity, cutout current 10mA]
Eac: 500V, 1min[Normal temperature, normal humidity, cutout current 20mA]
Edc: 500V, 100MW min. [Normal temperature, normal humidity]
Power
switching
circuit
Overcurrent
detection
circuit
Control circuit
588m/s
2
2
(40G)[A instllation]
(60G)[B, C instllation]
2
2
(20G)[A instllation]
(60G)[B, C instllation]
2
(60G)
2
(2G)[3 directions, each 1h, Sweep time 10min]
Output rectifying
and smoothing
circuit
Remote ON/OFF
change over switch
Overvoltage
detection
circuit
Output
voltage
detection
circuit
004-02 / 20060214 / ea111_rtw.fm
+RC
+S
+
RC
S
DC output
(14/19)

Related parts for RTW281R8