JWS10048/A TDK Corporation, JWS10048/A Datasheet

POWER SUP 100W 48V 2.1A ENCLOSED

JWS10048/A

Manufacturer Part Number
JWS10048/A
Description
POWER SUP 100W 48V 2.1A ENCLOSED
Manufacturer
TDK Corporation
Series
JWSr
Type
Industrialr
Datasheets

Specifications of JWS10048/A

Power Supply Type
Switching (Closed Frame)
Voltage - Output
48V
Number Of Outputs
1
Power (watts)
100W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 2.1A
Size / Dimension
7.4" L x 3.62" W x 1.97" H (188mm x 91.9mm x 50mm)
Power (watts) - Rated
100.8W
Operating Temperature
-10°C ~ 50°C
Efficiency
79%
Approvals
CE, CSA, DENTORI, EN, UL, VDE
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
48V
Output Current
2.1A
Power Rating
100.8W
Input Voltage
85V AC To 265V AC Or 120V DC To 330V DC
Brand/series
JWS Series
Configuration
Enclosed
Current, Output
2.1 A (Max.)
Frequency, Operating
63 Hz
Line Regulation
192 mV
Load Regulation
240 mV
Output
48 VDC @ 2.1 A
Power, Output
100 W
Primary Type
AC-DC
Special Features
PFC, Remote Sense
Standards
UL Listed, CSA Certified, EN60950, VDE Approved, CE Approved, Built to Meet DENTORI
Temperature, Operating
-10 to 50 °C
Voltage, Input
85 to 265/120 to 330 VAC/VDC
Voltage, Output
48 VDC
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1060
JWS100-48/A
*10. Ratings - Derating at standard mounting.
*11. As for DENTORI, built to meet at 100VAC.
*1. At 100/200VAC, Ta=25°C and maximum output power.
*2. For cases where conformance to various safety specs (UL, CSA, EN) are required,
*3. Measure with EIAJ RC-9131 probe, Bandwise of scope :100MHz.
*4. 85 - 265VAC , constant load.
*5. No load-Full load, constant input voltage.
*6. Constant current limit with automatic recovery.
*7. OVP circuit will shut down output, manual reset (Line recycle).
*8. At 100/200VAC nominal output voltage and maximum output current.
*9. Measured by the each measuring method of UL,CSA,EN and DENTORI(at 60Hz).
*Read instruction manual carefully, before using the power supply unit.
10 Output Voltage Range
11 Maximum Ripple & Noise
12 Maximum Line Regulation
13 Maximum Load Regulation
14 Temperature Coefficient
15 Over Current Protection
16 Over Voltage Protection
17 Hold-up Time (Typ)
18 Leakage Current
19 Remote Sensing
20 Parallel Operation
21 Series Operation
22 Operating Temperature
23 Operating Humidity
24 Storage Temperature
25 Storage Humidity
26 Cooling
27 Withstand Voltage
28 Isolation Resistance
29 Vibration
30 Shock (In package)
31 Safety
32 Conducted Emission
33 Radiated Emission
34 Weight(Typ)
35 Size (W.H.D)
1 Nominal Output Voltage
2 Maximum Output Current
3 Maximum Output Power
4 Efficiency (Typ)
5 Input Voltage Range
6 Input Current (100/200VAC)(Typ) (*1) A
7 Inrush Current(Typ)
8 PFHC
9 Power Factor (100/200VAC)(Typ) (*1) -
A159-01-01/A-A
ITEMS
input voltage range will be 100-240VAC(50/60Hz).
=NOTES=
JWS 100/A
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve (A159-01-02/A_).
(*3) -10 ~ 0°C mV
MODEL
0 ~ +50°C mV
(*10) -
(*11) -
(*1) %
(*2) -
(*4) mV
(*5) mV
(*6) A
(*7) -
(*8) -
(*9) -
mm
W
V
A
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
SPECIFICATIONS
3.79-4.95
2.85-3.63
JWS100
1.0/0.5
0.75mA MAX, 0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC
-3/A
21 ~
120
160
3.3
20
66
67
20
40
More than 100M at 25°C and 70%RH Output - FG...500VDC
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B.
Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B.
14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start
Approved by UL1950, CSA950, EN60950,VDE0160.
5.75-6.75
JWS100
-10 ~+50°C ( -10 ~+40°C:100%, +50°C:60%)
4.5-5.5
At no operating, 10-55Hz (Sweep for 1min)
85 - 265VAC (47-63Hz) or 120 - 330VDC
50 x 92 x 188 ( Refer to Outline Drawing )
-5/A
100
120
160
21 ~
Output - FG : 500VAC (100mA) for 1min
20
75
20
40
5
19.6m/s
Built to meet EN61000-3-2
30 ~ 90%RH (No dewdrop)
10 ~ 95%RH (No dewdrop)
Less than 196.1m/s
Built to meet DENTORI.
13.8-16.2
10.8-13.2
JWS100
Convection Cooling
Less than 0.02%/°C
2
-12/A
8.92 ~
102
150
180
Constant, X,Y,Z 1h each.
8.5
12
76
48
96
-30 ~ +85°C
0.99/0.95
Possible
Possible
1.4/0.7
20ms
700
-
17.3-20.3
13.5-16.5
JWS100
-15/A
7.35 ~
105
150
180
120
15
77
60
7
2
DENSEI-LAMBDA
27.6-32.4
21.6-26.4
JWS100
-24/A
4.72 ~
108
150
180
150
4.5
24
79
96
55.2-64.8
43.2-52.8
JWS100
-48/A
100.8
2.2 ~
200
240
192
240
2.1
48
79

Related parts for JWS10048/A

JWS10048/A Summary of contents

Page 1

JWS 100/A A159-01-01/A-A MODEL ITEMS 1 Nominal Output Voltage 2 Maximum Output Current 3 Maximum Output Power 4 Efficiency (Typ) 5 Input Voltage Range 6 Input Current (100/200VAC)(Typ) (* Inrush Current(Typ) 8 PFHC 9 Power Factor (100/200VAC)(Typ) (*1) ...

Page 2

JWS 100/A A159-01-02/A Ta(°C) MOUNTING A -10 ~+ 100 -10 0 MOUNTING A MOUNTING B (STANDARD MOUNTING) OUTPUT DERATING LOAD(%) MOUNTING B MOUNTING C 100 100 100 80 100 60 80 ...

Page 3

JWS 100/A A159-01-03/A-C MODEL ITEMS 1 Nominal Output Voltage 2 Maximum Output Current 3 Maximum Output Power 4 Efficiency (Typ.) 5 Input Voltage Range 6 Input Current (100/200VAC) (Typ.) (* Inrush Current (Typ.) 8 PFHC 9 Power Factor ...

Related keywords