GPC50A SL Power Electronics Manufacture of Condor/Ault Brands, GPC50A Datasheet

no-image

GPC50A

Manufacturer Part Number
GPC50A
Description
POWER SUP SWITCHER 50W TRIPLE
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
GPC50r
Datasheet

Specifications of GPC50A

Rohs Status
RoHS non-compliant
Voltage - Output
5V, ±12V
Number Of Outputs
3
Power (watts)
50W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 5A
2nd Output
12 VDC @ 2A
3rd Output
-12 VDC @ 500mA
Size / Dimension
6.3" L x 3.92" W x 1.57" H (160mm x 99.6mm x 39.9mm)
Power (watts) - Rated
50W
Operating Temperature
0°C ~ 50°C
Efficiency
65%
Approvals
CE, CSA, IEC, UL
Line Regulation
2%, 5%, 3%
Load Regulation
2%, 5%, 3%
4th Output
-
• Wide-range ac input 85-264 Vac
• 2-year warranty
• Approved to UL1950, IEC950 and CSA22.2-234 L3
• Meets FCC and CISPR22 Class B conducted
• Triple outputs
• RoHS Compliant Model Availalbe (G suffix)
SPECIFICATIONS
Ac Input
85-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated output load: 1.5 A
Hold-Up Time
20 ms minimum from loss of ac input at full load, nominal line (115 Vac).
Output Power
50 W continuous, 60 W peak. Peak ratings are for 60 s maximum duration,
10% duty cycle. During peak load condition, output regulation may exceed
total regulation limits.
Overload Protection
Fully protected against short circuit and output overload.
Short circuit protection is cycling type power limit on outputs 1 & 2; foldback
type on output 3. Recovery after fault is automatic. See output ratings chart
for additional notes or conditions.
Overvoltage Protection.
Crowbar provided on V1.
Efficiency
65% at full rated load, nominal input voltage, depending on model and load
distribution.
Turn-on Time
Less than 1 second at 120 Vac, 25°C (inversely proportional to input voltage
and thermistor temperature).
Input Protection
Internal ac fuse provided. Designed to blow only if a catastrophic failure oc-
curs in the unit.
Inrush Current
Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start
conditions will not exceed 34 A.
Temperature Coefficient
0.03%/°C typical on all outputs.
emissions requirements
GLOBAL PERFORMANCE SWITCHERS
Summary:
All specifications are typical at nominal input, full load at 25
marked to LVD
O
C unless otherwise stated
50 WATT GLOBAL PERFORMANCE SWITCHERS
Environmental
Designed for 0 to 50°C operation at full rated output power; derate output current
and total output power by 2.5% per °C above 50°C. See Environmental and
Packaging Specifications on next page.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise
probe directly across output terminals of the power supply.
Transient Response
Main output—500 μs typical response time for return to within 0.5% of final value
for a 50% load step change. ∆i/ ∆t<0.2 A/μs. Maximum voltage deviation is 3.5%.
Startup/ shutdown overshoot less than 3%.
Voltage Adjustment
Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following emissions require-
ments:
EMI SPECIFICATIONS
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Leakage Current
0.7 mA 254 Vac @ 60 Hz input.
Safety
Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950; UL file
#E135803 commercial; CSA #LR46516 all models. All DC outputs are SELV under
normal and single fault conditions.
GPC50 Commercial
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kH
EN61000-4-5, 1 kV diff., 2 kV com.

Related parts for GPC50A

GPC50A Summary of contents

Page 1

GLOBAL PERFORMANCE SWITCHERS Summary: • Wide-range ac input 85-264 Vac • 2-year warranty • Approved to UL1950, IEC950 and CSA22.2-234 L3 • Meets FCC and CISPR22 Class B conducted emissions requirements • Triple outputs • RoHS Compliant Model Availalbe (G ...

Page 2

... Commercial Model Output No. Output GPC50A + -12 V GPC50F + - Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load maintain these regulation conditions, the 5.1 V current must be at least 1 and not greater than 5 times the V2 current. ...

Related keywords