HC24-2.4-AG POWER ONE, HC24-2.4-AG Datasheet - Page 6

LINEAR SUPPLY 24V/2.4A OUTPUT

HC24-2.4-AG

Manufacturer Part Number
HC24-2.4-AG
Description
LINEAR SUPPLY 24V/2.4A OUTPUT
Manufacturer
POWER ONE
Series
Linearr
Type
Regulated Linearr
Datasheets

Specifications of HC24-2.4-AG

Voltage - Output
24V
Number Of Outputs
1
Power (watts)
57W
Applications
Commercial
Power Supply Type
Linear, Regulated (Open Frame)
Voltage - Input
100, 120, 220, 240VAC
Mounting Type
Chassis Mount
1st Output
24 VDC @ 2.4A
Size / Dimension
5.62" L x 4.87" W x 2.95" H (142.8mm x 123.7mm x 74.9mm)
Power (watts) - Rated
57W
Operating Temperature
0°C ~ 50°C
Efficiency
60%
Approvals
CE, CSA, cUL, EN, IEC, TUV, UL
Line Regulation
±0.05%
Load Regulation
±0.05%
Input Voltage
87 to 110|104 to 132|191 to 242|209 to 264 V
Output Voltage
24 V
Maximum Output Current
2.4 A
Input Frequency
47 to 63 Hz
Product
Linear
Commercial/medical
Commercial
Output Power Rating
58 W
Output Voltage (channel 1)
24 V
Output Current (channel 1)
2.4 A
Mounting Style
Chassis
Dimensions
5.62 in L x 4.87 in W x 2.95 in H
Output Type
Isolated
Configuration
Open-Frame
Operation
Linear
Output
24 VDC @ 2.4 A
Primary Type
AC-DC
Special Features
Remote Sense
Voltage, Input
100 to 264 VAC
Voltage, Output
24 VDC
Worldwide Ac Input Capabilities
100/120/220/230/240 VAC
Output Current (max)
2.4A
Screening Level
Commercial
Product Length (mm)
142.75mm
Product Height (mm)
74.93mm
Product Depth (mm)
123.7mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Package / Case
Case C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
179-2323

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HC24-2.4-AG
Manufacturer:
PowerOne
Quantity:
2
MCD10016 Rev. 1.2, 13-Nov-09
Environmental Specifications
PARAMETER
Operating Temperature
Storage Temperature
Temperature Coefficient
Shock
Vibration
Relative Humidity
CONDITIONS/DESCRIPTION
Derate output power linearly above 50°C by 3% per °C.
0°C to 50°C (after 15 minute warm-up).
24 hours after warm-up.
Operating.
Random vibration from 10 Hz to 2 kHz, 3 axis.
Non-Condensing.
Page 6 of 9
Linear Power Supplies Data Sheet
At 100% load
At 40% load
-0.3
MIN
-40
0
5
NOM
0.1
www.power-one.com
+0.3
6.15
MAX
0.3
50
70
85
20
95
UNITS
%/°C
G
%RH
G
°C
°C
°C
%
RMS
PK