GLC65AG SL Power Electronics Manufacture of Condor/Ault Brands, GLC65AG Datasheet - Page 2

PWR SPLY TRIPLE 5,12,-12V 65W

GLC65AG

Manufacturer Part Number
GLC65AG
Description
PWR SPLY TRIPLE 5,12,-12V 65W
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
GLC65r
Datasheet

Specifications of GLC65AG

Voltage - Output
5V, ±12V
Number Of Outputs
3
Power (watts)
65W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 7A
2nd Output
12 VDC @ 3A
3rd Output
-12 VDC @ 2.5A
Size / Dimension
5" L x 3" W x 1.25" H (127mm x 76.2mm x 31.8mm)
Power (watts) - Rated
65W
Operating Temperature
0°C ~ 50°C
Efficiency
80%
Approvals
CE, CSA, EN, UL
Line Regulation
2%, 5%, 6%
Load Regulation
2%, 5%, 6%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Other names
271-2317
Notes:
A. Continuous individual output ratings for unrestricted convection cooling. Combination of individual output loads must not exceed total power rating.
B. Peak rating for 60 s 10% duty cycle or continuous rating 150 LFM forced air cooling.
C. Adjustment on V1 varies all outputs simultaneously (1% on V1 @ 1% on V2 & V3).
D. Total combined current of V1 & V2 not to exceed 12 A. Combination of individual output loads must not exceed total power rating.
E. Total regulation is defined as maximum deviation from the initial set point. With all other outputs at 50% load, output under test can be varied from 0 to 100% load
and varied to any ac line voltage. Initial set point is 1% on V1, 2% on V2 and 3% on V3
F. Add “G” suffix to model number for RoHS compliant model.
SL Power Electronics Corp., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 09/10/08. Data Sheet ©
2008 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
GLC65 MECHANICAL SPECIFICATIONS
Commercial
Model
GLC65A
GLC65B
GLC65D
GLC65E
GLC65G
GLC65H
ENVIRONMENTAL SPECIFICATIONS
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
Medical
Model
GLM65A
GLM65B
GLM65D
GLM65E
GLM65G
GLM65H
Output No.
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
OPERATING
0 TO 50°C
0 to 95% RH
20 g
-500 to 10,000 ft
1.5 g
pk
rms’
0.003 g
Output
+5.0 V
+5.1 V
+5.0 V
+5.0 V
+5.0 V
+3.3 V
+3.3 V
+5.0 V
+12 V
+15 V
+24 V
+24 V
+12 V
+12 V
+12 V
-12 V
-15 V
-12 V
2
/Hz
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 g
-500 to 40,000 ft
5 g
Maximum (A)
rms’
pk
Output
0.026 g
2.5 A
2.5 A
1.5 A
2.5 A
1.5 A
2.5 A
2.5 A
2.5 A
3 A
7 A
2 A
7 A
7 A
5 A
4 A
5 A
4 A
7 A
2
/Hz
Maximum (B)
Output
A. Units should be allowed to warm up/operate under non-condensing con-
ditions before application of power. Derate output current and total output
power by 2.5% per °C above 50°C. For operation in a confined space, moving
air may be required. Under all conditions, the cooling vs. load profile should
be such that heat sinks and/or heatsink temperatures do not exceed 90 °C
for extended periods.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogo-
nal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz,
3 orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-op-
erating.
2.5 A
2.5 A
5 A
4 A
9 A
4 A
3 A
9 A
4 A
9 A
4 A
8 A
5 A
4 A
8 A
6 A
3 A
9A
Regulation (E)
Total
3.5%
4.5%
2%
5%
6%
2%
4%
5%
2%
3%
6%
2%
3%
6%
3%
3%
6%
6%
1.20
30.28
V1 Adjustment
Note (C)
± 5%
± 5%
± 5%
± 5%
± 5%
± 5%
6.2 ± 0.6 V
6.2 ± 0.6 V
6.2 ± 0.6 V
6.2 ± 0.6 V
6.2 ± 0.6 V
4.3 ± 0.8 V
OVP Set-
point
Ripple/
Noise
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%