HE28-6-AG POWER ONE, HE28-6-AG Datasheet - Page 4

no-image

HE28-6-AG

Manufacturer Part Number
HE28-6-AG
Description
LINEAR POWER SUPPLY 28V 6AMP SGL
Manufacturer
POWER ONE
Series
Linearr
Datasheets

Specifications of HE28-6-AG

Voltage - Output
28V
Number Of Outputs
1
Power (watts)
168W
Applications
Commercial
Power Supply Type
Linear, Regulated (Open Frame)
Voltage - Input
120VAC
Mounting Type
Chassis Mount
1st Output
28 VDC @ 6A
Size / Dimension
14" L x 4.87" W x 3.53" H (355.6mm x 123.7mm x 89.7mm)
Power (watts) - Rated
168W
Operating Temperature
0°C ~ 50°C
Efficiency
60%
Approvals
CE, CSA, cUL, EN, IEC, TUV, UL
Line Regulation
±0.05%
Load Regulation
±0.05%
Output Current (max)
6A
Output Voltage
28V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Length (mm)
355.6mm
Product Height (mm)
89.66mm
Product Depth (mm)
123.7mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Screw
Package / Case
Case E
Product
Linear
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Power-One’s No-Bus™ POL converters provide sophisticated power
management capabilities without the cost and complexity of third-party
controllers and the communication bus interfaces required by analog
architectures.
Power-One’s bus-programmable POL solutions combine many
innovative operating concepts to achieve an unprecedented level of
power-system integration. A multitude of parameters, such as output
voltages, sequencing, tracking, and protection limits are user-
programmed via I
Although Z-One
it does not require users to provide an I
or non-volatile memory; Z-One
autonomously in any system. Additional features include:
number of unique models in inventory.
outputs from 0.5 to 5.5 VDC.
power density, and cost.
incompatibility issues.
Open architecture based on industry standard I
Wide input ranges and programmable outputs reduce the
Extremely scalable architecture provides up to 32 programmable
Significantly reduced component count improves reliability,
GUI-driven configuration and simulation simplifies power
system development, accelerating time to market.
Fully-integrated point-of-load solution eliminates component
Manages up to four analog components including VRMs, POLs,
fans, and linear regulators.
temperature via signal pins.
undervoltage, and Power Good
track the output voltage settings.
Reporting of output current and
Thresholds for overvoltage,
2
Signals and Protections
Output voltages (0.5 to 5.5 V) and turn-on delays are configured
Up to four No-Bus POLs can current share using a single control trace.
No-Bus POLs can start up with pre-biased outputs.
Sink and source current capabilities for active bus termination.
with an external resistor and a capacitor, respectively.
®
2
Digital Power can be programmed via an I
C, or GUI, and stored in a Digital Power Manager.
Output Voltages and Currents
®
9 mm
Digital Power can operate
2
ZM7300 Digital
Power Managers
C interface, host processor,
Bus Programmable POL Solutions
2
C interface.
No-Bus POL Converters
Z-One
2
C bus,
TM
TM
®
Digital Power
t
t
ZM7300 Series controllers can manage analog components
(including VRMs, linear regulators, POLs, and fans) and Z-POL
converters for a total of 32 devices. I
systems in 100 kbs and 400 kbs modes of operation is supported.
These 9 x 9mm QFN-package controllers can be purchased
preprogrammed, or can be user programmed via an IEEE 1149.1
compliant JTAG port or via the Z-Series GUI and the I
Additional features include:
Ensures data integrity by storing configuration instructions in
non-volatile memory.
Collects I
output current, POL temperature, and protection status).
Monitors the intermediate bus, accepts interrupts, initiates
crowbar protection, and interfaces with dc-dc bus converters
and ac-dc front ends.
Bus Converter
IBA Regulated
System
Host
2
C compatible POL performance data (output voltage,
Frequency synchronization and
Comprehensive sequencing and
Feedback loop compensation and
Frequency synchronization, fault
phase interleaving reduce EMI.
cascading management.
enable logic.
propagation, and current sharing are
implemented, without external
components, by interconnecting
pins on the Z-POLs being
coordinated.
Simple Pin Strapping
Coordination and
Optimization via
PC-Based
GUI
2
C communication with host
2
C port.

Related parts for HE28-6-AG