GNT400
Front End Series 400W AC/DC
Universal Input Medical & ITE Power Supply
•Medical (EN60601-1) and ITE (EN60950) Certifications
•Compact 4” x 7” x 1.5” U Channel (1U compatible)
•9.5 W/in³
•100-240 VAC Input with Active PFC
•12 to 48 V DC Output at 400W (300W convection rating)
•5 Vdc, 100 mA Standby Output
•12 Vdc Fan Output
•Approved to UL, CSA, and EN/IEC Standards
•Less than 100µA leakage
•Compliance to EN55011/22 Conducted Noise, Class B
•RoHS Compliant – Category 6
GNT
AC Input
Input Current
Inrush Current
Input Fuses
Power Factor
Earth Leakage Current
Output Power
Peak Output Power
Output Voltage
Voltage Adjustability
Minimum Load
Total Regulation
Transient Response
Remote Sense
Specifications
SL Power Electronics Corp
______________________________________________________________________________________________________________________________
4
XX
X
100-240VAC, 50/60 Hz, 1∅. 90-270VAC, 45-65 Hz max
X
X
G
RoHS Com pliant
Cover Options: Blank = Standard Mini Cover, "E" = Cover w ith fan on the end, "T" = Cover w ith fan on top
Output Connections: "B" = Busbars, "T" = Phoenix P/N 1731721
Input Connections: "A" = EBY P/N 5002-03-N-12, "B" = Phoenix P/N 1732034, "C" = AMP P/N 540445-5 (pins 2 & 4
Output Voltage: (See m odels chart below )
Output Pow er (Watts): "4" = 400W
Product Fam ily
500µs to 1%, 50% load step, i/ t < 0.2A/µs
•
Compensates for up to 500mV voltage drop
6050 King Drive Ventura, CA 93003
F1 and F2, 6.3A/250V for line and neutral
400W continuous with 200lfm airflow
Maximum voltage deviation is 3.5%
450W for 1 minute, 10% duty cycle
100µA at 120VAC, 60 Hz Normal
120VAC: 4.2A. 230VAC: 2.1A
See chart for convection ratings
400µA at 264VAC, 50 Hz, SFC
Active Circuit, 37A max. peak
0.99 typical, 0.96 minimum
±5% minimum
Not required
Model Number Key
See chart
See chart
•
Phone 805.486.4565 • Fax 858.712.2040
All Specifications are typical at nominal input, full load at 25
Turn On Time
Hold-up Time
Over/Undershoot
Overload Protection
Overvoltage Protection
Ripple and Noise
ITE Safety Standards
Medical Safety Standards
Thermal Considerations
these temp. indicates sufficient cooling: T5: 90°C max., T1: 100°C max
Switching Frequency
MTBF
Overtemperature Protection
Efficiency
Temperature Coefficient
•
Email: info@slpower.com
Output: 170kHz ±8kHz, PFC: 140kHz ±8kHz
Keeping the following components below
EN/IEC/UL 60601-1, CSA22.2 No. 601-1
0.03% per °C typical on all units
0.1µF and 10 µF caps on probe
°
C unless otherwise stated.
1% pk-pk max., 20MHz BW
2 Year Warranty
Cycling type, 470W typical
CSA/EN/IEC/UL 60950-1
300K hours per Telcordia
91% typical at 230VAC
88% typical at 120VAC
•
www.slpower.com
20 ms at 400W
500 ms max
3.5% max
See chart
Automatic
1 of 4