RSC350DBB-CF SL Power Electronics Manufacture of Condor/Ault Brands, RSC350DBB-CF Datasheet

no-image

RSC350DBB-CF

Manufacturer Part Number
RSC350DBB-CF
Description
PS SWITCH 350W QUAD W/COVER FAN
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
RSC35xr
Datasheet

Specifications of RSC350DBB-CF

Voltage - Output
5V, 12V, 12V, 24V
Number Of Outputs
4
Power (watts)
350W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 132VAC, 180 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 40A
2nd Output
24 VDC @ 6A
3rd Output
12 VDC @ 4A
4th Output
12 VDC @ 4A
Size / Dimension
9.5" L x 5" W x 3.59" H (241.3mm x 127mm x 91.2mm)
Power (watts) - Rated
350W
Operating Temperature
0°C ~ 50°C
Efficiency
74%
Approvals
CE, CSA, EN, IEC, UL
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
78
RSC350
SPECIFICATIONS:
Ac Input
90-132 and 180-264 Vac. 50/60 Hz single phase
Input Current
9/4.5 A
Hold-Up Time
20 ms minimum from loss of ac input at full load, nominal line (115 Vac).
Output Power
350 W with cover fan option (390 W) peak).
Overload Protection
Standard on all outputs, recovery automatic.
Overvoltage Protection
Standard on all outputs within ranges below:
OUTPUT
5 V
12 V & 15 V
24 V & 28 V
Efficiency
74% minimum at full load; nominal input voltage.
Turn-on Time
Less than 2 seconds.
Input Protection
Internal ac fuse provided. Designed to blow only if a catastrophic
failure occurs in the unit-fuse does not blow on overload or short
circuit.
Inrush Current
60 A minimum
Temperture Coefficient
0.03%/°C typical on all units
Environmental
Designed for 0 to 50°C operation at full rated output power;
derate output current and total output power by 2.5% per °C
above 50°C. See Environmental and Packaging Specifications
on next page for additonal informaton.
Power Fail
A TTL signal goes low upon failure. 6mS min. before output drops 5%.
Output Noise
0.5% rms. 1% pk-pk measured directly across output terminals.
Transient Response
Main output- 500 µsec typical response time for return to within
0.5% of final value for a 50% boad step change. Di/Dt<0.2/µsec.
Maximum voltage deivation is 3.5%
Remote Sense
Standard on main output; will compensate for 0.5 V of cabling
losses.
Commercial/RSM350 Medical
OVP SETTING
5.6-6.8 V
18-22 V
29-35 V
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com
V ADJ. RANGE
4.6-5.5 V
11.5-15.3 V
22.0-30.0 V
FEATURES:
• Automatic line range selection
• Fully regulated and floating outputs
• Modular output configurations
• FCC/CISPR 11, 22
• Commercial Approved to UL1950, CSA 22.2 No.
• Medical Approved to UL2601-1, IEC601 and CSA 601.1
• “Smart Load” feature eliminates minimum load
• 2-year warranty
Voltage Adjustment
Built-in potentiometers adjust outputs minmum of ±5%.
Reverse Voltage Protection
All outputs protected against inadvertent application of reverse
voltage up to 1 times rated current of the reversed output.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following
emissions requirements:
EMI SPECIFICATION
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Commercial Leakage Current
100 µA
Commercial Safety
Approval to UL1950 (no D3 deviations). CSA 22.2 No. 234L6.
IEC950 and EN60950.
Medical Leakage Current
80 µA
Medical Safety
Approved to UL2601-1, IEC601, CSA601.1 for patient vicinity
(non-invasive applications. Consult factory for approval status.
Outputs are intended for Protectively Earthed Signal Output and
Intermediate Circuits only.
Outputs are not acceptable for patient connection without
additional isolation. The creepage distance between primary
and ground is 4 mm minimum, 8 mm between primary and
secondary circuits.
Vibration
Designed to meet requirements of MIL-STD 810E. Method 514.4
Category 1. This test consists of random vibration at 0.015g/Hz
from 5 to 50 Hz declining linearly to 0.15 g2/Hz in each axis for
one hour. Shock Designed to meet MIL-STD 810E. Method
516.4. Unpackaged units shall meet the bench handling require-
ments of procedures V1 for four drops per face.
234L6, IEC2950, EN60950
requirements
marked to LVD
350 Watt Multiple Output
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN61000-4.2, 6 kV contact 8 kV air
EN61000-4.3, 3 V/meter
EN610004-4, 2 kV. 5 kHz
EN61000-4-5, 1kV diff., 2 kV com

Related parts for RSC350DBB-CF

RSC350DBB-CF Summary of contents

Page 1

RSC350 Commercial/RSM350 Medical SPECIFICATIONS: Ac Input 90-132 and 180-264 Vac. 50/60 Hz single phase Input Current 9/4.5 A Hold-Up Time 20 ms minimum from loss of ac input at full load, nominal line (115 Vac). Output Power 350 W with ...

Page 2

RSC350 Commercial/RSM350 Medical ...

Related keywords