FNP1800-48G POWER ONE, FNP1800-48G Datasheet - Page 13

PWR SUP 1812W 48V FRONT END

FNP1800-48G

Manufacturer Part Number
FNP1800-48G
Description
PWR SUP 1812W 48V FRONT END
Manufacturer
POWER ONE
Series
FNP1800r
Type
Commercial, Industrialr
Datasheets

Specifications of FNP1800-48G

Voltage - Output
12V, 48V
Number Of Outputs
2
Power (watts)
1800W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 39.2A
2nd Output
12 VDC @ 1A
Size / Dimension
11" L x 1.6" W x 5.6" H (279.4mm x 40.5mm x 141.2mm)
Power (watts) - Rated
1812W
Operating Temperature
0°C ~ 50°C
Efficiency
90%
Approvals
CE, cUL, EN, TUV, UL
Product
Switching
Commercial/medical
Commercial
Output Power Rating
1546 W
Input Voltage
85 VAC to 264 VAC
Output Voltage (channel 1)
48 V
Output Current (channel 1)
39.2 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
1 A
Mounting Style
Rack
Dimensions
11 in L x 5.6 in W x 1.6 in H
Brand/series
FNP1800 Series
Configuration
Enclosed
Operation
Linear
Output
12 VDC @ 1 A, 12 VDC @ 1 A, 12 VDC @ 1 A, 48 VDC @ 25.4 A, 48 VDC @ 32.2 A, 48 VDC @ 39.2 A
Power, Output
1812, 1512, 1212 W
Primary Type
AC-DC
Special Features
PFC
Voltage, Input
230 VAC
Voltage, Output
12, 12, 12, 48, 48, 48 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
179-2397
CLOCK, I
Auxiliary power +12 V
(Output 2)
Auxiliary power ground
(Output 2)
Logic Gnd
Output margin PSU 1
Output margin PSU 2
Output margin PSU 3
NC
NC
NC
NC
NC
NC
SUB-D Output Connector Pinout and Signal Specification (Continued)
Synchronized start-up circuit for paralleling operation
Because of hiccup overcurrent protection, when a supply reaches an overcurrent limit, the output voltage will
immediately turn OFF and after a delay turn ON again. In parallel use, all power supplies have to start synchronized
because of the internal hiccup behavior. Otherwise, the supply which has reached overcurrent first will go to hiccup;
this will overload the other supplies, which then will also go to hiccup. When the first supply has recovered from
hiccup (hiccup dead time), the others remain in hiccup. This will immediately drive the first one into hiccup once
again. This means that without a start-up circuit, a system with several power supplies can never recover from an
overload condition or start-up into full load.
The following additional circuit, required to reach synchronized startup, is already implemented inside the
FNR-3-12G and FNR-3-48G shelves.
MCD10074 Rev. 1.2, 15-Apr-10
Output Connector
Description
2
C clock line
Location
Pin
28
25
26
27
29
30
31
32
33
34
35
36
37
Internally connected over 10
GND. Wire separately from auxiliary and main output
GND to minimize noise and avoid voltage drops on
signal- and I
V
V
o2
o2
V
V
V
+ Aux output, insulated from main output
- Aux output, insulated from main output
sense-
sense-
sense-
2
Open or connected to V
Open or connected to V
Open or connected to V
C return. Leave open if not used.
Page 13 of 17
referenced to logic GND
(+8 % V
(+8 % V
(+8 % V
I
2
C compatible signal
o1
o1
o1
Type
) or V
) or V
) or V
& FNR-3 Power Shelf Data Sheet
sense+
sense+
sense+
to V
o2
(-8 % V
(-8 % V
(-8 % V
sense-
sense-
sense-
-, Auxiliary
FNP1500/1800 Front-Ends
o1
o1
o1
)
)
)
5 V or 3.3 V logic
High level
Low level
www.power-one.com
V max
I max
60V
60V
60V

Related parts for FNP1800-48G