NLP150L-96S3 Emerson Network Power, NLP150L-96S3 Datasheet - Page 2

POWER SUPPLY 3.3V SINGLE 110W

NLP150L-96S3

Manufacturer Part Number
NLP150L-96S3
Description
POWER SUPPLY 3.3V SINGLE 110W
Manufacturer
Emerson Network Power
Series
NLP150Lr
Datasheets

Specifications of NLP150L-96S3

Rohs Status
RoHS non-compliant
Voltage - Output
3.3V
Number Of Outputs
1
Power (watts)
150W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
3.3 VDC @ 22A
Size / Dimension
3.8" L x 6.8" W x 1.26" H (96.5mm x 172.7mm x 32mm)
Power (watts) - Rated
110W
Operating Temperature
0°C ~ 50°C
Efficiency
73%
Approvals
CSA, UL, VDE
Line Regulation
±2%
Load Regulation
±2%
Power Supply Output Type
Fixed
No. Of Outputs
1
Output Voltage
3.3V
Output Current
22A
Power Rating
150W
Input Voltage
90V AC To 264V AC
Length
172.72mm
Product
Switching
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
393-1042
NLP150L Series
Notes
1
2
3
4
5
6
7
8
9
10
11
12
13
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Please consult our website for the following items:
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 110-150W AC/DC Universal Input Switch Mode Power Supplies
Free air convection.
Multiple output units: maximum continuous output power not to exceed
110W and the output current not to exceed: I
300LFM forced air cooling from the longer side.
Multiple output units: maximum continuous output power not to exceed
150W and the output current not to exceed: I
Peak power at 115% lasting less than 30 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total regulation limits.
Figure is peak-to-peak for room temperature rating. Output noise
measurements are made across a 20MHz bandwidth using a 6 inch twisted
pair, terminated with a 10µF electrolytic capacitor and a 0.1µF ceramic
capacitor.
Minimum load required for correct start-up and operation on single outputs
and on main output of multiple versions. Failure to observe minimum load
on main output will not allow the supply to start-up correctly. Some
electronic test loads have a large delay time before they start drawing
current even though the voltage from the supply is present. During this time
delay, there is no load on the output and as a result, the supply may not be
able to start-up properly and maintain its correct output voltage. In these
instances, a dummy resistive load across the output may be necessary to
load the output of the supply until the test load can function correctly and
draw the intended minimum load. Minimum load required on auxiliary
outputs to maintain regulation.
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4G
rms 5Hz to 500Hz.
For optimum reliability no part of the heatsink should exceed 110°C and no
semi-conductor case temperature should exceed 115°C.
CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
The EMI specifications reference measurements made with the power
supply mounted on a grounded metal sheet extending 1 inch beyond each
edge, using an unshielded cable. No external filtering required during
conducted emissions testing but some applications may require additional
filtering to achieve system compliance
All models require a minimum mounting stand-off of 6.35mm (0.25 inches)
in the end use product.
Operational range 90VAC to 264VAC.
For 3.3V ouput (single), typical efficiency is 69%.
VOLTAGE
+5.1V (V
+3.3V (V
+5.1V (V
+12V (V
+24V (V
OUTPUT
+12V (V
+12V (V
3.3V (V
5.1V (V
24V (V
48V (V
A
A
A
A
A
C
A
C
A
B
B
)
)
)
)
)
)
)
)
)
)
)
S i n g l e a n d t r i p l e o u t p u t s
MIN
0.15A
0.3A
0.1A
1.5A
0.5A
0.6A
0.5A
1A
1A
0A
0A
(5)
OUTPUT CURRENT
MAX
A
A
+I
+I
9.2A
4.6A
2.3A
9.2A
2.0A
22A
22A
20A
10A
2A
6A
B
B
+2(I
+2(I
(1)
C
C
)≤23A.
)≤32A.
Application Note
300 LFM
12.5A
12.5A
6.5A
3.2A
3.0A
30A
30A
30A
15A
3A
8A
(2)
International Safety Standard Approvals
150W
110W
VDE0805/EN60950/IEC950
UL1950
0 C 10 C 20 C 30 C 40 C 50 C 60 C 70 C
RIPPLE
DERATING CURVE
Output Power (Watts)
120mV
240mV
480mV
120mV
120mV
240mV
50mV
50mV
50mV
50mV
50mV
300 LFM FORCED
(4)
AIR COOLING
CONVECTION
NATURAL
COOLING
REGULATION
TOTAL
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±5.0%
±2.0%
±2.0%
±5.0%
File Name: NLP150LST.PDF Rev: 24 June 2002
www.artesyn.com
NLP150L-96T536
NLP150L-96T658
NLP150L-96S3
NLP150L-96S5
NLP150L-96S6
NLP150L-96S8
NLP150L-96S9
NUMBERS
MODEL
55W
75W
2

Related parts for NLP150L-96S3