Page 1
... Electrical specifications pertaining to FE power modules are included in the following matrices as well as sense and signaling connection information. Please note that for the FE power module to function properly, the proper connections must be made on the 25- pin connector. These connections are described in the Sense and Signaling matrices for both stand-alone module use and for modules assembled in a standard FE Series racking system ...
Page 2
... LAMBDA ELECTRONICS FE Power Module Signals Connector Interface FE power modules utilize a standard 25-pin D-type connector for sense and signaling terminations. The proper interface should include a complimentary mate and guide-pins to ensure proper insertion alignment. Lambda recommends the following mating interface Amp Incorporated Harrisburg, PA 17105 717-564-0100 (telephone) Amp Model Nos ...
Page 3
... LAMBDA ELECTRONICS RATINGS AND SPECIFICATIONS FOR LAMBDA MODEL NO. FE2000: I. MAXIMUM RATINGS AT V NOMINAL OUT SPECIFICATION UNITS OUTPUT VOLTAGE RANGE OUTPUT CURRENT (POWER) A (W) AT 50ºC ( OUTMIN OUTPUT CURRENT (POWER) A (W) AT 60ºC ( OUTMIN OUTPUT CURRENT (POWER) A (W) AT 70ºC ( OUTMIN OPERATING TEMPERATURE º ...
Page 4
... SIGNALS ARE ISOLATED FROM POWER SUPPLY OUTPUT AND EACH OTHER FOR VOLTAGES UP TO 500VDC MAXIMUM AND 3000VAC ISOLATION FROM AC INPUT TO AUXILIARY SIGNALS. THE CURRENT MONITOR SIGNAL IS REFERENCED TO THE -IMON TERMINAL (THE CATHODE OF THE INTERNAL OR-ING DIODE.) LAMBDA ELECTRONICS INCOPORATED 515 BROAD HOLLOW ROAD, MELVILLE, NY 11747-3700 • TEL: 516-694-4200 • 516-293-0519 ...
Page 5
... OUTPUT TO CHASSIS GROUND 1500VAC, INPUT TO CHASSIS GROUND LEAKAGE CURRENT (AC LESS THAN 3.5mA WHEN OPERATED AT 250VAC (47-63Hz) OR LOWER LINE TO CHASSIS GROUND) VOLTAGES. REGULATORY AGENCY FE SERIES POWER MODULES ARE COMPLAINT TO THE FOLLOWING COMPLIANCE STANDARDS: UL1950 CSA 22.2-234 EN60950 CE MARKED FOR EUROPEAN COMMUNITY COMPLIANCE V ...
Page 6
... CONDITION HAS OCCURRED. THIS PIN REPRESENTS THE COLLECTOR OF THE INTERNAL OPTO-TRANSISTOR CAPABLE OF SINKING UP TO 5mA WITH 20 VOLTS MAXIMUM APPLIED FROM COLLECTOR TO EMITTER. Lambda FE Series Safety and Installation Instructions for Lambda Model FE2000 LAMBDA ELECTRONICS INCOPORATED 515 BROAD HOLLOW ROAD, MELVILLE, NY 11747-3700 • TEL: 516-694-4200 • 516-293-0519 ...
Page 7
... LAMBDA ELECTRONICS To comply with published safety standards, the following instructions must be used in conjunction with the Lambda FE Series: For earth fault protection, the unit must be protected in the final installation by suitable overcurrent protection means. If protection relies upon building wiring, the end product installation must ensure that the necessary protection is provided ...
Page 8
... Im spezeillen ist auf das Einhalten ausreichender Kreich- und Luftstrecken sowie Isolationsdicken zwischen dem Primä- und Sekundärkreis sowie zum Schutzleiter su achten. Das Netzteil liefert eine SELV-Spannung in Übereinstimmung mit IEC-950. Die verfugbare Ausgangsleistung ist grober 240VA. Das CE-Konformitatszeichen auf dem produkt zeigt Ubereinstimmung mit den anforderungen der EG-neiderspannungs-Richtlinie [72/23/EEC] and siener Erganzung [93/68/EEC] ...
Page 9
... LAMBDA ELECTRONICS LAMBDA ELECTRONICS INCOPORATED 515 BROAD HOLLOW ROAD, MELVILLE, NY 11747-3700 • TEL: 516-694-4200 • 516-293-0519 I M NSTRUCTION ANUAL Outline Drawing P. 9 FE2000 SERIES IMFE2000 ...