BLP40-3000G POWER ONE, BLP40-3000G Datasheet

no-image

BLP40-3000G

Manufacturer Part Number
BLP40-3000G
Description
PWR SUP 40W 5V,12V,-12V OUT TRPL
Manufacturer
POWER ONE
Series
BLP40r
Datasheet

Specifications of BLP40-3000G

Voltage - Output
5V, ±12V
Number Of Outputs
3
Power (watts)
40W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
100 ~ 250VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 5A
2nd Output
12 VDC @ 3A
3rd Output
-12 VDC @ 1A
Size / Dimension
3" L x 5" W x 1.23" H (76.2mm x 127mm x 31.2mm)
Power (watts) - Rated
40W
Operating Temperature
0°C ~ 70°C
Efficiency
70%
Approvals
CB, CE, EN, IEC, UL
Line Regulation
±2%, ±5%
Load Regulation
±2%, ±5%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Other names
179-2273
Ordering Information:
OPTIONS
RoHS lead-solder exemption
RoHS compliant for all 6 substances
MCD10027 Rev. 1.0
Single Output Model Selection
BLP40-1005
BLP40-1012
BLP40-1024
Triple Output Model Selection
BLP40-3000
BLP40-3003*
* Advanced Product Release
NOTES:
Description
The BLP40 Series’ economical and compact construction provides single or three-output ac-dc power conversion to
meet the requirements of networking and data communications systems, as well as commercial and industrial
configurations.
The BLP40 is rated for convection, as well as forced-air cooling. Full output power is available with external
forced-air cooling. Other features include main-output remote sense and an internal EMI filter.
MODEL
MODEL
1
2
3
4
10 CFM or 150 LFM (average measurement of six equally-distanced points through a 3.5” x 1.6” cross-sectional area) with power supply mounted
Peak current duration for less than 30 Sec with a maximum duty cycle of 10%.
At 25 °C ambient including voltage set point tolerance, line, and load regulation.
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth, and bypass capacitors of 10 μF and 0.1 μF.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
on 0.25” standoffs. Recommended airflow direction is from the AC side to the DC side.
NOMINAL OUTPUT
NOMINAL OUTPUT
VOLTAGE (VDC)
VOLTAGE (VDC)
5V
12V
24V
+5V
+12V
-12V
+5V
+15V
-15V
MIN-MAXIMUM OUTPUT
CURRENT, CONVECTION
MIN-MAXIMUM OUTPUT
CURRENT, CONVECTION
0.1 to 1.5A
0.0 to 0.5A
0.1 to 1.5A
0.0 to 0.5A
0 to 2.1A
0 to 1.1A
0.3 to 3A
0.3 to 3A
0 to 5A
No RoHS suffix character required.
Add “G” as the last character of the part number.
SUFFIXES TO ADD TO PART NUMBER
MIN-MAXIMUM OUTPUT
MIN-MAXIMUM OUTPUT
0.0 to 0.7A
0.0 to 0.7A
Page 1 of 5
CURRENT 1
0 to 3.3A
0 to 1.8A
CURRENT 1
0.3 to 4A
0.1 to 2A
0.3 to 4A
0.1 to 2A
0 to 8A
Features
• RoHS lead-free solder and lead-solder-exempted
• Industry-standard 3” x 5” footprint
• Main output remote sense
• CE marked to Low Voltage Directive (Pending)
• Compliance to EN61000-4-2/-3/-4/-5/-6/-8
products are available
BLP40 AC-DC Series Data Sheet
PEAK OUTPUT
PEAK OUTPUT
CURRENT 2
CURRENT 2
3.7A
1.9A
2.5A
9A
5A
3A
5A
1A
1
REGULATION % 3
REGULATION % 3
TOTAL
TOTAL
±2
±2
±2
±2
±5
±5
±2
±5
±5
www.power-one.com
40 Watts
RIPPLE & NOISE
RIPPLE & NOISE
%p-p 4
%p-p 4
1
1
1
1
1
1
1
1
1

Related parts for BLP40-3000G

BLP40-3000G Summary of contents

Page 1

... The BLP40 is rated for convection, as well as forced-air cooling. Full output power is available with external forced-air cooling. Other features include main-output remote sense and an internal EMI filter. Single Output Model Selection ...

Page 2

... Overvoltage Protection Main output. Short Circuit Protection Fully-protected against output short circuit. MCD10027 Rev. 1.0 BLP40 AC-DC Series Data Sheet Vin = 115 VAC, Max Power, 25 °C. Vin = 230 VAC, Max Power, 25 °C. See Model Selection Table See Model Selection Table -5%, +10% ...

Page 3

... CFM or 150 LFM (average measurement of six equally-distanced points through a 3.5” x 1.6” cross-sectional area) with power supply mounted NOTES: on 0.25” standoffs. Recommended airflow direction is from the AC side to the DC side. MCD10027 Rev. 1.0 BLP40 AC-DC Series Data Sheet on completed assemblies. Conducted: Conducted: ...

Page 4

... LOCATION) RECOMMENDED MATING CONNECTORS CN1 MOLEX 09-50-8031 LEOCO 3940S030000 CN2 MOLEX 09-50-8061 LEOCO 3940S060000 CN3 MOLEX 22-01-3027 LEOCO 2530S020000 Page BLP40 AC-DC Series Data Sheet CN1 - AC CONN. PIN 1 NEUTRAL PIN 2 MISSING PIN PIN 3 LINE CN2 - DC CON Ø 0.16 (4 PL) (4.1) PIN 1 ...

Page 5

... RECOMMENDED MATING CONNECTORS HOUSING CN1 MOLEX 09-50-8031 LEOCO 3940S030000 CN2 MOLEX 09-50-8061 LEOCO 3940S060000 CN3 MOLEX 22-01-3027 LEOCO 2530S020000 Page BLP40 AC-DC Series Data Sheet CN1 - AC CONN. PIN 1 NEUTRAL PIN 2 MISSING PIN PIN 3 LINE CN2 - DC CON Ø 0.16 (4 PL) (4.1) PIN 1 ...

Related keywords