GLC110-5G SL Power Electronics Manufacture of Condor/Ault Brands, GLC110-5G Datasheet

no-image

GLC110-5G

Manufacturer Part Number
GLC110-5G
Description
POWER SUPPLY SWITCHER 110W 5V
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
GLC110r
Datasheet

Specifications of GLC110-5G

Voltage - Output
5V
Number Of Outputs
1
Power (watts)
110W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
Size / Dimension
7" L x 4.25" W x 1.3" H (177.8mm x 108mm x 33mm)
Power (watts) - Rated
110W
Operating Temperature
0°C ~ 50°C
Efficiency
85%
Approvals
CE, CSA, IEC, UL
Line Regulation
2%
Load Regulation
2%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
1st Output
-
3rd Output
-
2nd Output
-
4th Output
-
• Cost-effective power source
• Single- and dual-output units
• Low height (1.30”)
• 2-year warranty
• Power fail signal standard
• Commercial Approved to UL60950-1, EN60950-1,
• Medical Approved to UL2601-1, EN60601-1,
• Complies with EN61000-3-2 Class A
• RoHS Compliant Model Available (G suffix)
SPECIFICATIONS
Ac Input
90-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at 90 Vac, 60 Hz with full rated output load not to
exceed 2.9 A.
Hold-up Time
20 ms minimum from loss of ac input at full load, nominal line (120 Vac).
Output Power
Normal continuous output power is 75 W for unrestricted natural convection,
or 110 W with 26 cfm air flow.
Output Regulation
Load regulation on dual output models is measured by ±40% load change
from 60% rated load and input voltage change from minimum to maximum
ratings.
Output #1 requires 1A minimum load for proper regulation of other outputs.
Initial set tolerance is measured with all outputs at 60% of full rated load.
Load regulation for single-output models measured by changing load from
5% to 50% load or 50% to full load in either direction.
Voltage Adjustment
Output #1 adjustment is ±5%. Note: output #1 must not be more than 1%
below nominal to achieve full output regulation on output #2. High voltage
settings may degrade the reliability of the unit due to excessive power
dissipation in some outputs.
Overload Protection
Fully protected against short circuit and output overload. Short circuit protec-
tion is cycling type power limit. Factory set to begin power limiting at 120 W.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with
noise probe directly across output terminals of the power supply.
POWER FAIL
Power fail signal is TTL or CMOS compatible (output goes low <0.5 V) 5 ms
before output voltage drops more than 4% below nominal voltage upon
loss of AC power. The signal is factory set to trip on 84 to 94 Vac brown-out
depending upon incoming line impedance and distortion. Other settings are
available to the user through adjustment of built in potentiometer (consult
factory for assistance). Output will stay low for 20 ms minimum.
GLOBAL PERFORMANCE SWITCHERS
FEATURES:
CSA22.2 No. 950-95 3rd Ed.
CSA-C22.2 No. 601.1
All specifications are typical at nominal input, full load at 25
GLC110 Commercial/GLM110 Medical
O
C unless otherwise stated
Transient Response
Main Output: 500 μs typical response time for return to within 0.5% of final value
for a 50% load step change, ∆i/∆t<0.2 A/μs. Maximum voltage deviation is 3.5%.
Startup/shutdown overshoot less than 3%. Turn-On Time less than 1 second at 120
Vac, 25.
Overvoltage Protection
Built in on main output.
Efficiency
72-85% depending on model.
Input Protection
Internal ac fuse provided on all units. Designed to blow only if a catastrophic
failure occurs in the unit.
Inrush Current
Inrush limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac
half-cycle under cold start conditions will not exceed 37 A.
Temperature Coefficient
0.03%/°C typical on all outputs.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following emissions require-
ments:
EMI SPECIFICATIONS
Conducted Emissions GLC110
Conducted Emissions GLM110
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Line Frequency Harmonics
Commercial Safety
All GLC models are approved to UL60950-1, CSA22.2 No. 950-95 3rd Ed, and
EN60950-1.
Medical Safety
All GLM models are approved to UL2601-1, CSA-C22.2 No. 601.1, EN60601-1.
110 Watt Global Performance Switchers
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN55011 Class B: FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
EN61000-3-2 Class A

Related parts for GLC110-5G

GLC110-5G Summary of contents

Page 1

... A. Temperature Coefficient 0.03%/°C typical on all outputs. EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions require- ments: EMI SPECIFICATIONS Conducted Emissions GLC110 Conducted Emissions GLM110 Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility Line Frequency Harmonics Commercial Safety All GLC models are approved to UL60950-1, CSA22 ...

Page 2

... A. Rating with unrestricted convection cooling. Total power not to exceed output can exceed rated current. B. Rating with 26 cfm forced air cooling. Total power not to exceed 110 maintain regulation V1 current must be at least 1/5 of V2. V1 must not be adjusted more than 1% below nominal and have at least 10% of rated load. GLC110/GLM110 MECHANICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS OPERATING Temperature ( 50° ...