PLP75-1012G POWER ONE, PLP75-1012G Datasheet

PWR SUP 75W 12V 7A OUTPUT

PLP75-1012G

Manufacturer Part Number
PLP75-1012G
Description
PWR SUP 75W 12V 7A OUTPUT
Manufacturer
POWER ONE
Series
PLP75r
Datasheet

Specifications of PLP75-1012G

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
75W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 5.4A
Size / Dimension
5" L x 3" W x 1.38" H (127mm x 76.2mm x 35mm)
Power (watts) - Rated
75W
Operating Temperature
-20°C ~ 70°C
Efficiency
80%
Approvals
CB, CSA, EN, TUV, UL
Line Regulation
±2%
Load Regulation
±2%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
179-2286
Applications
Description
The PLP75 is a cost-effective and efficient series of AC-DC power supplies suited for telecom, datacom, and many
other applications. The PLP75 Series meets the international information technology safety standards with the CE-
Mark for the European Low Voltage Directive (LVD). Active power-factor-correction (PFC) is a standard feature.
PFC enables the user to comply with EN 61000-3-2 line harmonics requirements. In addition, PFC reduces line
losses and rms input current to help achieve low-cost operation and makes the end product more environmentally
friendly to the end users.
Single-Output Model Selection
MCD10025 Rev. 1.1
1
supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC side to the DC side.
2
3
4
5
5 CFM or 150 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm cross-sectional area) with power
Peak current duration for less than 30 seconds with a maximum duty cycle of 10%.
At 25 °C ambient including voltage set point tolerance, line and load regulation
Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
Output is adjustable ±10 % of nominal.
PLP75-1003G
PLP75-1005G
PLP75-1012G
PLP75-1024G
PLP75-1048G
Telecom, datacom
Networking
Industrial
Medical instrumentation
Consumer
Gaming
Model
Model numbers highlighted in yellow or shaded are not recommended for new designs.
Output Voltage
Nominal
(VDC)
3.3
12
24
48
5
5
5
5
5
5
Current (Amps),
Min-Max Output
Convection
0.1 - 5.4
0.1 - 2.7
0.1 - 1.4
0.2 - 13
0.2 - 13
Page 1 of 6
Min-Max Output
Current (Amps),
Forced Air
Features
0.1 - 6.5
0.1 - 3.1
0.1 - 1.6
0.2 - 15
0.2 - 15
75 Watts with 5 CFM forced-air cooling
Typical 80% efficiency
65 Watts with convection cooling
85-264 VAC wide-range input
FCC & CISPR 22, Class "B" – Conducted EMI
Power Factor Corrected (meets IEC61000-3-2)
Typical 0.99 power factor
Height meets 1U chassis constraints
Two-year limited warranty
Safety Agency pending to UL60960-1, CSA 22.2No.
60950-1-03, and TUV EN60950/IEC 60950-1
Compliance with EN 61000-4-2 level 4 (ESD),
EN 61000-4-3 (RF), EN 61000-4-4 level 3 (Fast
Transient/Burst), EN 61000-4-5 class 3 (Surge)
RoHS compliant for all six substances
PLP75 AC-DC Series Data Sheet
1
Peak Output
(Amps)
Current
17.5
16.5
3.5
1.8
7
2
Regulation
Total
(%)
±2
±2
±2
±2
±2
www.power-one.com
3
75 Watts
pk-pk %
Ripple &
Noise
1
1
1
1
1
4

Related parts for PLP75-1012G

PLP75-1012G Summary of contents

Page 1

... Nominal Output Voltage (VDC) 5 PLP75-1003G 3.3 5 PLP75-1005G 5 5 PLP75-1012G 12 5 PLP75-1024G 24 5 PLP75-1048G CFM or 150 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" cross-sectional area) with power supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC side to the DC side. ...

Page 2

... VAC, Max power, 25 °C 230 VAC, Max power, 25 °C Input fuse Non-user serviceable internally located AC input line fuse is provided. Efficiency At maximum output power, nominal line MCD10025 Rev. 1.1 PLP75 AC-DC Series Data Sheet Conditions/Description Page Watts Min. Nom. Max. Units ...

Page 3

... Gain margin. 1 See Model Selection tables. Fault Protection Parameter Current Limit set point Overload protected - power limit. Short-circuit protection Provided on all models. OVP Trip Vo1. MCD10025 Rev. 1.1 PLP75 AC-DC Series Data Sheet Conditions/Description Conditions/Description Page Watts Min. Nom. Max. Units 1 Watts 1 ...

Page 4

... Operating: Random vibration 500 Hz (10 minutes, each axis). Non-Operating: Random vibration 500 Hz (10 minutes, each axis). Shock Operating: half-sine, 11 ±3 ms, 3-axis. Non-Operating: half-sine, 11 ±3 ms, 3-axis. MCD10025 Rev. 1.1 PLP75 AC-DC Series Data Sheet Conditions/Description Conditions/Description Level 4. Level 3. Level 3. Class 3. Conditions/Description Conditions/Description ...

Page 5

... Mounting distance Note 1 The minimum distance from the bottom of the component leads (solder side) or top of the components (component side) to the customer's metal chassis should be at least 0.113 " (2.85 mm). MCD10025 Rev. 1.1 PLP75 AC-DC Series Data Sheet Conditions/Description Conditions/Description Page Watts Min. ...

Page 6

... Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10025 Rev. 1.1 PLP75 AC-DC Series Data Sheet 5.00 +/- 02 4.55 Page Watts CONN ...

Related keywords