Specifications of 412-59585-G

Accessory Type
Cover
Product
Kits
For Use With/related Products
Power One MAP80 Series Power Supplies
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
179-2296
Description
Multiple Output Model Selection –
MCD10144 Rev. 1.0, 02-Feb-10
Single Output Model Selection
MAP80-1005
MAP80-1012
MAP80-1024
NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
Power-One’s MAP80 Series of power supplies provides reliable, tightly-regulated DC power for commercial and
industrial systems which require high peak current capabilities. Wide-range AC input and full international safety, EMI,
and ESD compliance ensure worldwide acceptance. All units bear the CE Mark.
The MAP80 utilizes a variable frequency design with a thermally efficient U-channel chassis to provide full power
operation in convection-cooled applications. Design innovations include metric and SAE mounting inserts on each
mounting surface to provide integration flexibility. Dual-mode connectors provide traditional terminal block connections
or popular single-row Molex connector mating.
Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific
output voltage requirements.
MODEL
MAP80-4000
MAP80-4001
MAP80-4002
MAP80-4003
MAP80-4004
MODEL
Model numbers highlighted in yellow or shaded are not recommended for new designs.
2) MAP80-1012 output currents are expressed as 12V/15V operation. MAP80-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
12V/15V
24V/28V
VOLTAGE
VOLTAGE
OUTPUT
OUTPUT
+12V
+24V
+12V
+12V
+12V
+15V
+24V
+15V
-12V
-12V
-12V
-15V
-15V
+5V
+5V
+5V
+5V
+5V
-5V
-5V
5V
11.52V to 12.48V
23.04V to 24.96V
11.52V to 12.48V
14.40V to 15.60V
23.04V to 24.96V
11.5V to 15.5V
23.0V to 29.0V
4.5V to 5.6V
ADJUSTMENT
4.8V to 5.5V
4.8V to 5.5V
4.7V to 5.5V
4.8V to 5.5V
4.8V to 5.5V
ADJUSTMENT
RANGE
RANGE
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
80W Continuous Output Power
3.8/3.2A (Note 2)
7.5/6A (Note 2)
MAXIMUM OUTPUT
CURRENT
CURRENT
OUTPUT
16A
3.5A
14A
14A
14A
14A
14A
4A
1A
1A
2A
1A
1A
4A
1A
1A
1A
1A
2A
1A
1A
Page 1 of 4
9.2/7.3A (Note 2)
4.6/3.9A (Note 2)
CURRENT (NOTE 1)
CURRENT (NOTE 3)
PEAK OUTPUT
PEAK OUTPUT
3.5A
3.5A
16A
16A
16A
16A
16A
7A
1A
1A
1A
1A
7A
1A
1A
6A
1A
1A
1A
1A
18A
Features
• RoHS lead-solder-exemption compliant
• Wide-range input for 110/220 VAC applications
• CE marked to Low Voltage Directive
• Input transient & ESD compliance to
• Meets EN55022, Class B limits
• TTL compatible Power Fail Signal
• Greater than 175,000 Hours MTBF
• Metric and SAE mounting inserts
MAP80 AC-DC Series Data Sheet
EN61000-4-2/-3/-4
REGULATION
REGULATION
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
LINE
0.2%
0.2%
0.1%
LINE
REGULATION
REGULATION
0.5%
±1%
LOAD
LOAD
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
RIPPLE & NOISE
%p-p (NOTE 2)
RIPPLE & NOISE
%p-p (NOTE 1)
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1.4%
0.5%
1%
www.power-one.com
-11.5V to -12.5V
-11.5V to -12.5V
-11.6V to -12.4V
-14.4V to -15.5V
-14.4V to -15.5V
11.9V to 12.1V
24.0V to 24.1V
11.5V to 12.5V
12.0V to 12.1V
11.6V to 12.4V
14.6V to 15.1V
24.0V to 24.1V
14.4V to 15.5V
11.76V to 12.15V
-4.8V to -5.4V
-4.8V to -5.4V
INITIAL SETTING
23.8V to 24.2V
5.1V to 5.2V
5.1V to 5.2V
5.1V to 5.2V
5.1V to 5.2V
5.1V to 5.2V
INITIAL SETTING
5.0V to 5.1V
ACCURACY
ACCURACY

Related parts for 412-59585-G

412-59585-G Summary of contents

Page 1

Description Power-One’s MAP80 Series of power supplies provides reliable, tightly-regulated DC power for commercial and industrial systems which require high peak current capabilities. Wide-range AC input and full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear ...

Page 2

Multiple Output Model Selection (Cont.) OUTPUT ADJUSTMENT MODEL VOLTAGE RANGE +5V 4.8V to 5.5V +12V 11.52V to 12.48V MAP80-4010 -5V Fixed -12V Fixed +5V 4.8V to 5.5V +12V 11.52V to 12.48V MAP80-4020 -12V Fixed -5V Fixed NOTES: 1) Peak loads ...

Page 3

... Options DESCRIPTION NOTES Cover Add ‘C’ suffix to model number or order part number 412-59585-G separately. For convection cooled applications, derate output power to 65 watts on all multiple output models and MAP80-1005. Derate MAP80-1012 and MAP80-1024 to 75 watts. MCD10144 Rev. 1.0, 02-Feb-10 MAP80 AC-DC Series Data Sheet ...

Page 4

OVERALL SIZE: 7.20" x 4.20" x 1.80" (182.9mm x 106.7mm x 45.7mm) INPUT & OUTPUT CONNECTIONS: 6-32 SCREW WIRE CLAMPS ON 0.312" (7.9mm) CENTERS, 0.045" (1.1mm) SQUARE PINS ON 0.156" (3.9mm) CENTERS, MATES WITH MOLEX SERIES 2139, 6442, OR 41695 ...

Related keywords