HS2214ECB61H Renesas Electronics America, HS2214ECB61H Datasheet

no-image

HS2214ECB61H

Manufacturer Part Number
HS2214ECB61H
Description
DEV EMULATOR PCB ADAPTOR
Manufacturer
Renesas Electronics America
Datasheet

Specifications of HS2214ECB61H

Accessory Type
User Interface Cable
For Use With/related Products
H8S/2214
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
To our customers,
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Renesas Electronics website:
Old Company Name in Catalogs and Other Documents
http://www.renesas.com
April 1
Renesas Electronics Corporation
st
, 2010

Related parts for HS2214ECB61H

HS2214ECB61H Summary of contents

Page 1

To our customers, Old Company Name in Catalogs and Other Documents st On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the ...

Page 2

All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm ...

Page 3

... H8S/2214Series TBP-112 User System Interface Cable (HS2214ECB61H) for E6000 Emulator User’s Manual ...

Page 4

Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with ...

Page 5

... Thank you for purchasing this user system interface cable (HS2214ECB61H) for the Renesas’s original microcomputer H8S/2214series. The HS2214ECB61H is a user system interface cable that connects an H8S/2214 series E6000 emulator (HS2214EPI61H; hereinafter referred to as the emulator) to the IC socket for a TBP-112 package for the H8S/2214 series MCU on the user system. ...

Page 6

Section 1 Configuration....................................................................................1 Section 2 Connection Procedures ......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station ......................................... 3 2.2 Connecting User System Interface Cable to User System ................................................ 5 2.2.1 Soldering the IC Socket ....................................................................................... 5 2.2.2 Inserting Cable ...

Page 7

... Section 1 Configuration Use an CSPACK112A1110H01 socket (socket (manufactured by Tokyo Eletech Corporation) for the TBP-112 package IC socket on the user system. Figure 1 shows the configuration of the HS2214ECB61H user system interface cable for the TBP-112 package. To emulator station Spacer Cover Figure 1 HS2214ECB61H User System Interface Cable ...

Page 8

... Table 1 lists the HS2214ECB61H components. Please make sure you have all of these components when unpacking. Table 1 HS2214ECB61H Components No. Component 1 Cable body 2 Cable head 3 IC socket 4 Spacer 5 Cover 6 Screws (M1 mm) 7 Driver 8 Documentation 2 Quantity Remarks 1 Includes flat cable 1 1 For the TBP-112 package ...

Page 9

Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure will result in a FIRE HAZARD and will damage the user system and the emulator product or will ...

Page 10

Figure 2 Connecting User System Interface Cable to Emulator Station 4 ...

Page 11

Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 ...

Page 12

Notes on soldering the IC socket a) The IC socket is larger than the actual IC package; therefore, refer to figure 7 for the installation of other components not install components that occupy large volume close to ...

Page 13

CAUTION 1. Never dip the IC socket in flux or use wash to clean the IC socket. This is because flux may remain inside the IC socket due to the IC socket’s structure. When using the IC socket with other ...

Page 14

Inserting Cable Head Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an TBP-112 package on the user system with pin 1 on the user system interface cable head, and insert the ...

Page 15

... If the emulator does not operate correctly, cracks might have occurred in the solder. The user system interface cable (HS2214ECB61H) head and the IC socket for the TBP-112 package on the user system have no pin dedicated for alignment. Use the follow procedure to fasten the cable head ...

Page 16

Next, fasten screws to and should be tightened a little at a time, alternating between screws on opposing corners. Figure 5 Fastening Cable Head Procedure ( little, so that four screw holes are aligned. Then, each screw ...

Page 17

Fastening Cable Body Connect the cable body to the cable head. Figure 6 Fastening Cable Body 11 ...

Page 18

Recommended Dimensions for User System Mount Pad Figure 7 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an TBP-112 package (CSPACK112A1110H01: socket (manufactured by Tokyo Eletech Corporation). Note that ...

Page 19

Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 8. Figure 8 Dimensions for User System Interface Cable Head 13 ...

Page 20

Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 9. Figure 9 Resulting Dimensions after Connecting User System Interface Cable 14 ...

Page 21

Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a provided screwdriver. 3. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be ...

Page 22

Figure 10 Installing MCU to User System 16 ...

Page 23

Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2214 series, turn on the emulator according to the procedures described in the H8S Series E6000 Emulator User's Manual (HS2000EPI61HE). 2. Verify the user system interface cable connections ...

Page 24

Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount ...

Related keywords