Primary Attributes
-
DEVICE FAULT OPERATION
Table 12. Fault / Warning
46
33742
FUNCTIONAL DEVICE OPERATION
OPERATIONAL MODES
Notes
V2LOW (e.g., V2 < 4.0V)
49.
50.
51.
VDD Over-temperature
CAN Over-temperature
Table 12
CANH Short to VSUP
HS Over-temperature
CANL Short to VSUP
CANH Short to GND
CANH Short to VDD
CANL Short to GND
CANL Short to VDD
VDD Temperature
VDD Over-current
CAN Over-current
VDD Short-circuit
Watchdog Reset
HS Over-current
Fault / Warning
Pre-warning
Refer to descriptions of CANH and CANL short to GND, VDD, and VSUP elsewhere in table.
Peak current 150mA during TXD dominant only. Due to loss of communication, CAN controller reaches bus OFF state. Average current
out of V2 is below 10mA.
Over-current might be detected. THERM-CUR bit set in CAN register.
VSUP LOW
Battery Fail
describes the relationship between device fault or warning and the operation of the VDD, V2, CAN, and HS interface
VDD regulator enters linear
temperature Pre-warning or
mode. VDD under-voltage
warning or shutdown may
VDD under-voltage reset
reset may occurs. VDD
over-temperature Pre-
shutdown may occur
occurs. VDD over-
Warning flag only.
Leave as is
No change
No change
No change
No change
No change
No change
No change
No change
No change
No change
No change
No change
Turn OFF
Turn OFF
occur
VDD
ON
Turn OFF if VDD under-
voltage reset occurs
V2 out of range
No change
No change
No change
No change
No change
No change
No change
No change
No change
No change
No change
No change
Turn OFF
Turn OFF
Turn OFF
Turn OFF
V2
(50)
temperature falls, CAN is
re-enabled automatically
Turn OFF due to V2 low
and no communication
If V2 is OFF, turn OFF
No communication
No communication
No communication
Turn OFF due to V2.
Turn OFF due to V2.
Turn OFF due to V2.
Turn OFF due to V2.
Disable. As soon as
Communication OK
Communication OK
Communication OK
No communication
No communication
No communication
No communication
No change
No change
No change
No change
CAN
(49)
Analog Integrated Circuit Device Data
(51)
(51)
(51)
Freescale Semiconductor
Turn OFF if VDD under-
HS over-temperature
voltage reset occurs
No change
No change
No change
No change
No change
No change
No change
No change
No change
No change
No change
may occur
OFF
OFF
OFF
OFF
OFF
HS
.

Related parts for KIT33742DWEVB