FDB-1027 Finisar Corporation, FDB-1027 Datasheet - Page 2

no-image

FDB-1027

Manufacturer Part Number
FDB-1027
Description
EVAL BOARD SFP/SFP+
Manufacturer
Finisar Corporation
Datasheet

Specifications of FDB-1027

Main Purpose
Telecom, Fiber Optic Transceiver, SFP/SFP+
Embedded
No
Utilized Ic / Part
SFP/SFP+ Modules
Primary Attributes
SFP/SFP+ TXRX of 125Mb/s to 10.3Gb/s
Secondary Attributes
GUI, Four 50-ohm SMA Connectors
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
775-1006
FTLF8528P2BCV Pluggable SFP+ Product Specification – November 2007
I.
Notes:
1. Circuit ground is internally isolated from chassis ground.
2. T
3. Laser output disabled on T
4. Should be pulled up with 4.7k – 10kohms on host board to a voltage between 2.0V and 3.6V.
5. Rate select can also be set through the 2-wire bus in accordance with SFF-8472 v. 10.1
6. LOS is open collector output. Should be pulled up with 4.7k – 10kohms on host board to a voltage
© Finisar Corporation November 21, 2007 Rev. B
Pin
10
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
the host board if intended for use. Pull up voltage should be between 2.0V to Vcc + 0.3V. A high
output indicates a transmitter fault caused by either the TX bias current or the TX output power
exceeding the preset alarm thresholds. A low output indicates normal operation. In the low state, the
output is pulled to <0.8V.
MOD_ABS pulls line low to indicate module is plugged in.
Select is set at Bit 3, Byte 110, Address A2h. Tx Rate Select is set at Bit 3, Byte 118, Address A2h.
Note: writing a “1” selects maximum bandwidth operation. Rate select is the logic OR of the input
state of Rate Select Pin and 2-wire bus.
between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.
FAULT
Pin Descriptions
MOD_ABS
Symbol
is an open collector/drain output, which should be pulled up with a 4.7k – 10k Ohms resistor on
T
SDA
SCA
V
V
RD+
V
V
V
V
LOS
V
TD+
V
RS0
RS1
RD-
T
TD-
FAULT
CCR
CCT
EET
DIS
EER
EER
EER
EET
EET
Transmitter Ground (Common with Receiver Ground)
Transmitter Fault.
Transmitter Disable. Laser output disabled on high or open.
2-wire Serial Interface Data Line (MOD-DEF2)
2-wire Serial Interface Clock (MOD-DEF1)
Module Absent, connected to V
Loss of Signal indication. Logic 0 indicates normal operation.
Receiver Ground (Common with Transmitter Ground)
Receiver Ground (Common with Transmitter Ground)
Receiver Inverted DATA out. AC Coupled
Receiver Non-inverted DATA out. AC Coupled
Receiver Ground (Common with Transmitter Ground)
Receiver Power Supply
Transmitter Power Supply
Transmitter Ground (Common with Receiver Ground)
Transmitter Non-Inverted DATA in. AC Coupled.
Transmitter Inverted DATA in. AC Coupled.
Transmitter Ground (Common with Receiver Ground)
Tx Rate Select:
Open or Low =
Rx Rate Select:
Open or Low =
DIS
>2.0V or open, enabled on T
High =
High =
2.125 or 4.25 Gb/s Fibre Channel (Low Bandwidth)
8.5 Gb/s Fibre Channel (High Bandwidth)
2.125 or 4.25 Gb/s Fibre Channel (Low Bandwidth)
8.5 Gb/s Fibre Channel (High Bandwidth)
Name/Description
EET
or V
DIS
EER
<0.8V.
3
. Rx Rate
Page 2
Ref.
1
2
3
4
4
4
5
6
5
1
1
1
1
1

Related parts for FDB-1027