Page 1
... Test Procedure for the NCP1207AADAPGEVB 01/31/2005 1.0 Diagrams 1.1 Test Configuration Figure 1. NCP1207AADAPGEVB Test Configuration. ...
Page 2
... Oscilloscope Test Points Figure 2. NCP1207AADAPGEVB Oscilloscope Test Points. 2.0 Equipment • Variable AC Power supply (0 ~ 240 VAC, 1.0 A) • Ammeter (0 ~ 1.0 A) • Ammeter (0 ~ 3.0 A) • Voltmeter ( VDC) • Electronic Load (capable of sinking 3 VDC) • Oscilloscope (100 MHz, 120 V, 2-Channel) ...
Page 3
Test Procedure 3.1 Set load to 0.0 A. Apply 180 VAC supply. Verify that output voltage is 12.0 V ±1%. Input current should not exceed 20 mA. 3.2 Increase load current to 0.1 A. Gate driver and drain voltage ...
Page 4
Increase load current to 2.0 A. Gate driver and drain voltage should Figure 4. Verify that output voltage is 12.0 V ±1%. Input current should not exceed 200 mA. Figure 4. Gate Driver and Drain Voltage ...
Page 5
Notes 4.1 Oscilloscope channel 2 (drain) should be set to 10x. 4.2 The ground plane side of resistor convenient grounding point for the oscilloscope. ...