E6240 Atmel, E6240 Datasheet - Page 22

no-image

E6240

Manufacturer Part Number
E6240
Description
KIT EVAL/DEV USING QT60240-ISG
Manufacturer
Atmel
Series
Quantum, QMatrix™r
Datasheets

Specifications of E6240

Sensor Type
Touch, Capacitive
Sensing Range
16 / 24 Buttons/Keys
Interface
I²C, USB
Voltage - Supply
5V
Embedded
No
Utilized Ic / Part
QT60160, QT60240
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sensitivity
-
Typical values: For most touch applications, use the values shown in the outlined cells. Bold text items indicate default settings. The number to send to the QT is the number in
the leftmost column (0...15), not numbers from within the table. The QT uses lookup tables to translate the 0.. .15 to the parameters for each function.
NRD is an exception: it can range from 0...254 which is translated from 1 = 0.5s to 254 = 127s, in increments of 0.5s, with zero = infinity. 255 is illegal.
AWAKE is an exception: it can range from 1...255 which is translated from 1 = 0.1s to 255 = 25.5s , in increments of 0.1s. Zero is illegal.
DHT is an exception: it can range from 0...255 which is translated from 1 = 0.1s to 255 = 25.5s , in increments of 0.1s. Zero will disable DHT.
lQ
Number
Index
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
(Page 17)
counts
Per key
NTHR
- 10 -
11
12
13
14
15
16
17
18
19
4
5
6
7
8
9
(Page 17)
NDRIFT
Per key
- 2.5 -
secs
0.1
0.2
0.3
0.4
0.6
0.8
1.2
1.5
3.3
4.5
7.5
10
1
2
6
(Page 17)
PDRIFT
Per key
- 0.6 -
secs
0.1
0.2
0.3
0.4
0.8
1.2
1.5
2.5
3.3
4.5
7.5
10
1
2
6
(Page 18)
counts
Per key
Key off
NDIL
- 2 -
10
11
12
13
14
15
1
3
4
5
6
7
8
9
(Page 18)
Per key
counts
unused
FDIL
- 5 -
10
11
12
13
14
15
1
2
3
4
6
7
8
9
Table 6.2 Setups Lookup Table
(Page 18)
0.5 .. 127s
0 (Infinite)
Per key
Default=
secs
NRD
10s
(Page 20)
Per key
WAKE
- On -
Off
Parameter
22
(Page 19)
Per key
Pulses
- 48 -
BL
16
32
64
(Page 19)
Per key
- Off -
AKS
On
(Page 19)
SSYNC
Per key
- Off -
On
(Page 20)
SLEEP
Global
1,000
2,000
-125-
ms
250
500
16
32
64
(Page 19)
MSYNC
Global
QT60240-ISG R8.06/0906
- Off -
On
(Page 20)
0.1...25.5s
AWAKE
Default=
unused
Global
secs
2.5s
(Page 20)
0.1...25.5s
Default=
Global
secs
DHT
Off
1s

Related parts for E6240