STEVAL-MKI091V1 STMicroelectronics, STEVAL-MKI091V1 Datasheet - Page 33
![DEMO BOARD FOR LIS331DLM](/photos/9/19/91981/steval-mki091v1_sml.jpg)
STEVAL-MKI091V1
Manufacturer Part Number
STEVAL-MKI091V1
Description
DEMO BOARD FOR LIS331DLM
Manufacturer
STMicroelectronics
Series
MEMS, nanor
Datasheets
1.STEVAL-MKI009V1.pdf
(42 pages)
2.STEVAL-MKI091V1.pdf
(38 pages)
3.STEVAL-MKI091V1.pdf
(4 pages)
Specifications of STEVAL-MKI091V1
Sensor Type
Accelerometer, 3 Axis
Sensing Range
±2g, 4g, 8g
Interface
I²C, SPI
Sensitivity
64LSB/G, 32LSB/g, 16LSB/g
Embedded
No
Utilized Ic / Part
LIS331DLM
Acceleration
2 g, 4 g, 8 g
Sensing Axis
Triple Axis
Interface Type
I2C, SPI
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
LIS331DLM
Other names
497-10491
LIS331DLM
7.17
Table 44.
D6 - D0 bits set the minimum duration of the Interrupt 2 event to be recognized. Duration
steps and maximum values depend on the ODR chosen.
INT2_CFG (34h)
Table 45.
Table 46.
Configuration register for Interrupt 2 source.
Table 47.
D6 - D0
AOI
6D
ZHIE
ZLIE
YHIE
YLIE
XHIE
XLIE
AOI
AOI
0
0
INT2_DURATION description
INT2_CFG register
INT2_CFG description
Interrupt mode configuration
AND/OR combination of Interrupt events. Default value: 0.
(See table below)
6 direction detection function enable. Default value: 0.
(See table below)
Enable interrupt generation on Z high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on Z low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
Enable interrupt generation on Y high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on Y low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
Enable interrupt generation on X high event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on X low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
6D
Duration value. Default value: 000 0000
ZHIE
6D
0
1
Doc ID 15102 Rev 4
ZLIE
YHIE
OR combination of interrupt events
6 direction movement recognition
Interrupt mode
YLIE
Register description
XHIE
XLIE