STEVAL-ICB002V1 STMicroelectronics, STEVAL-ICB002V1 Datasheet - Page 8

BOARD EVAL TOUCH STM32/STMPE821

STEVAL-ICB002V1

Manufacturer Part Number
STEVAL-ICB002V1
Description
BOARD EVAL TOUCH STM32/STMPE821
Manufacturer
STMicroelectronics

Specifications of STEVAL-ICB002V1

Sensor Type
Touch, Capacitive
Sensing Range
3 Button/Key
Interface
USB
Voltage - Supply
3.3V
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
STMPE821
Silicon Manufacturer
STMicroelectronics
Kit Contents
Board
Features
PWM/GPIO Output, Multiple Touch Detection, Demonstrates Up To 3 Capacitive Touch Keys
Svhc
No SVHC (15-Dec-2010)
For Use With
497-10173 - BOARD EVAL S-TOUCH STM32
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Sensitivity
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
497-10167
STMPE821 functional overview
1.4
8/50
Calibration algorithm
The STMPE821 maintains 2 parameters for each TOUCH channel: TVR and CALIBRATED
IMPEDANCE. CALIBRATED IMPEDANCE is an internal reference of which, if the currently
measured IMPEDANCE exceeds the CALIBRATED IMPEDANCE by a magnitude of TVR, it
is considered a TOUCH.
If the IMPEDANCE is more than the CALIBRATED IMPEDANCE, but the magnitude does
not exceed CALIBRATED IMPEDANCE by TVR, it is not considered a TOUCH. In this case,
2 scenarios are possible:
1. Environmental changes has caused the IMPEDANCE to increase
2. Finger is near the sensing pad, but not near enough
In case 1, the change in IMPEDANCE is expected to be small, as environmental changes
are normally gradual. A value "EVR" is maintained to specify the maximum IMPEDANCE
change that is still considered an environmental change.
Table 3.
‘IMP’ and ‘CALIBRATED IMP’ used in this table is not the direct register read-out.
IMP = 127 - impedance register read-out
CALIBRATED IMP = 127 - calibrated impedance register read out.
ETC WAIT register state a period of time of which, all TOUCH inputs must remain "NO
TOUCH" for the next calibration to be carried out.
CAL INTERVAL states the period of time between successive calibrations when there are
prolonged NO TOUCH condition.
IMP>CALIBRATED IMP + TVR
IMP<CALIBRATED IMP + TVR
IMP>CALIBRATED IMP + EVR
IMP<CALIBRATED IMP + TVR
IMP<CALIBRATED IMP + EVR
IMP>CALIBRATED IMP
IMP>CALIBRATED IMP
IMP<CALIBRATED IMP
Calibration action under different scenarios
Scenario
Doc ID 14478 Rev 5
TOUCH,
no calibration
NO TOUCH,
no calibration
NO TOUCH,
new CALIBRATED IMP = previous CALIBRATED
IMP + change in IMP
CALIBRATED IMP + change in IMP
NO TOUCH,
new CALIBRATED IMP = new IMP
Touch sensing and calibration action
STMPE821