LM95214EB/NOPB National Semiconductor, LM95214EB/NOPB Datasheet - Page 27

no-image

LM95214EB/NOPB

Manufacturer Part Number
LM95214EB/NOPB
Description
BOARD EVALUATION FOR LM95214
Manufacturer
National Semiconductor
Series
PowerWise®r
Datasheets

Specifications of LM95214EB/NOPB

Sensor Type
Temperature
Sensing Range
-40°C ~ 140°C
Interface
SMBus (2-Wire/I²C)
Sensitivity
±1°C
Voltage - Supply
3 V ~ 3.6 V
Embedded
No
Utilized Ic / Part
LM95214
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
LM95214EB
Register Name
Status 3 (TCRIT2)
2.4.4 Status 3 (TCRIT2)
Status bits for TCRIT2. When one or more of these bits are set and if not masked the TCRIT2 output will activate. TCRIT2 will
deactivate when all these bits are cleared.
Bit(s)
7–5
4
3
2
1
0
Bit Name
-
R4T2
R3T2
R2T2
R1T2
LT2
Read/
Write
RO
RO
RO
RO
RO
RO
Command
Description
Reserved – will report "0" when read.
Remote 4 Tcrit Status:
1 – indicates that remote 4 reading is greater than or equal to the value set in Remote 4
Tcrit Limit register
0 – indicates that that remote 4 reading is less than the value set in Remote 4 Tcrit Limit
register minus the Common Hysteresis value
Remote 3 Tcrit Status:
1 – indicates that remote 3 reading is greater than or equal to the value set in Remote 3
Tcrit Limit register
0 – indicates that that remote 3 reading is less than the value set in Remote 3 Tcrit Limit
register minus the Common Hysteresis value
Remote 2 Tcrit-2 Status:
1 – indicates that remote 2 reading is greater than or equal to the value set in Remote 2
Tcrit-2 Limit register
0 – indicates that that remote 2 reading is less than the value set in Remote 2 Tcrit-2 Limit
register minus the Common Hysteresis value
Remote 1 Tcrit-2 Status:
1 – indicates that remote 1 reading is greater than or equal to the value set in Remote 1
Tcrit-2 Limit register
0 – indicates that that remote 1 reading is less than the value set in Remote 1 Tcrit-2 Limit
register minus the Common Hysteresis value
Local Tcrit Status:
1 – indicates that local reading is greater than or equal to the value set in Local Tcrit Limit
register
0 – indicates that local reading is less than the value set in Local Tcrit Limit register minus
the Common Hysteresis value
(Hex)
Byte
0x09
Read/
Write
RO
D7
27
D6
D5
R4T2 R3T2
D4
D3
R2T2
D2
R1T2
D1
LT2
D0
www.national.com
Default
(Hex)
POR

Related parts for LM95214EB/NOPB