EDK2378 Renesas Electronics America, EDK2378 Datasheet - Page 3

DEV EVAL KIT FOR H8S/2378

EDK2378

Manufacturer Part Number
EDK2378
Description
DEV EVAL KIT FOR H8S/2378
Manufacturer
Renesas Electronics America
Series
H8®r
Type
MCUr
Datasheets

Specifications of EDK2378

Contents
2G (Second-generation) Evaluation Board, HEW debugger support, Cable and CD-ROM
For Use With/related Products
H8S/2378
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
EDK2378 Quickstart Guide
Renesas Technology Europe Ltd.
3
1) Ensure that the EDK is connected to COM1, and power is applied.
2) Change to the debug session by choosing “SessionH8S_2000_HMon” from the drop down session menu.
3) If prompted to save session, click “No”.
4) If the Flash Control Bar is not greyed out (as below), then FDT is configured. Go to step 7.
5) If the FLASH control bar is greyed out in this mode, with only the magic wand visible, then the FDT settings for the
6) Choose “Save Session”, from the “File” menu.
7) Click on the “HMON FLASH Download Settings” button
8) Click on the “Boot” radio button,
9) Choose “Save Session”, from the “File” menu.
10) To connect to the EDK, press the connect icon
11) Right click on the “.abs” file in the “Download Module” section, and
12) When the “Please ensure that the device is in Boot mode”, (right),
13) Following completion of programming, a dialogue will appear
14) Press the disconnect icon to disconnect from the EDK
Programming the Board
board need to be set up. The FDT configuration wizard will appear. Follow steps below to setup FDT.
choose “Download Module”.
dialogue prompts you, push the BOOT mode button on the EDK, and
click “OK” in the dialogue.
prompting you to reset the EDK (below). Press the RESET button on
the EDK. The BOOT LED will go OFF, Click “OK” on the dialogue.
a.
b. Select your device from the drop down menu.
c.
d. Click the “Next” button
a.
b. If presented with the “Driver Selection” menu (above right),
c.
d. If presented with the “CPU Mode” window, click “OK”.
Click on the wand to start the wizard. (It may start automatically)
Click on the Kernels for your EDK. These are denoted by a
.EDK after the version.
If prompted for the “Target Configuration”, select the file
from the list matching your EDK, and click “OK”.
click on “serialdrv.dll” and then “OK”.
If presented with the “Configure Serial Driver” menu
(right), click on “Cancel”. There is no monitor on the board
for HEW to connect to, and so Hew will ask to make a
minimal connection. . Choose “Yes”, as this will allow you to
download the file in boot mode to the device.
and click “OK”.
.
.
.
.
D004886_11_v02
3

Related parts for EDK2378