R0K521134S000BE Renesas Electronics America, R0K521134S000BE Datasheet - Page 5

no-image

R0K521134S000BE

Manufacturer Part Number
R0K521134S000BE
Description
KIT EVAL STARTER FOR R8C/13
Manufacturer
Renesas Electronics America
Series
Renesas Starter Kits (RSK)r
Type
MCUr

Specifications of R0K521134S000BE

Contents
CPU Board, LCD Display Module, E8 Emulator, Cable, QuickStart Guide and CD-ROM
For Use With/related Products
R8C/13
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3. High-performance Embedded Workshop Workspace
High-performance Embedded Workshop integrates various tools such as compiler, assembler, debugger and editor into a common graphical
user interface. To learn more on how to user High-performance Embedded Workshop, open the High-performance Embedded Workshop
manual installed on your computer (Start Menu > All Programs > Renesas > High-performance Embedded Workshop > Manual Navigator).
17. Launch High-performance Embedded Workshop from the Start Menu. (Start Menu > All Programs > Renesas > High-performance
18. In the “Welcome” dialog box: Verify “Create New Workspace” is selected. Click <OK>.
19. In the “New Project Workspace” dialog box: Set the “CPU Family” to “M16C”, and verify the “Tool chain” is set to “Renesas M16C
20. Enter a name for the workspace. The project name will be automatically completed with the Workspace name. You can change this
21. On the “RSKR8C13- Step 1” window: Select “Tutorial” and click <Next>.
22. On the “RSKR8C13- Step 2” window: Click <Finish>.
23. On the Project Generator Information window: Click <OK>.
24. Select the Debug build configuration in the left hand drop down list on the toolbar.
25. Click on the “Build” icon to compile, assemble and link the project.
4. Programming and Debug
26. Ensure the “SessionR8C_E8_SYSTEM” session in the right hand drop down list on the toolbar is selected.
27. Click the <Connect> button on the debug toolbar.
28. The “Emulator mode” dialog will be shown. Select the correct device type
29. Select “Erase Flash and Connect”.
30. If the E8 is to provide power to the CPU board, select “Power Target from
31. Click <Next>
32. Ensure the “Enable advanced setting” checkbox is cleared.
33. Click <Next>, then <Finish>.
Embedded Workshop > High-performance Embedded Workshop)
Standard”. Select “RSKR8C13” from the left hand pane.
name to “Tutorial” if required. Click <OK>.
The project that is created has two configurations. The Release configuration can be used for the final release code version. The
Debug configuration allows modifications to the configuration for debugging.
(e.g. R5F21134 for RSKR8C13).
Please note that the “Emulator mode” wizard shown here will only
appear the FIRST time you connect to the target within a project. On
subsequent connections the “Emulator setting” dialog will appear,
please choose the same options to connect.
E8” and choose the “5.0V” option.
Otherwise connect a 5V centre positive supply.
D007054_11_S01_V04

Related parts for R0K521134S000BE