QB-179F124-T38MC Renesas Electronics America, QB-179F124-T38MC Datasheet - Page 13

no-image

QB-179F124-T38MC

Manufacturer Part Number
QB-179F124-T38MC
Description
179F IECUBE 38 SSOP T-TYPE
Manufacturer
Renesas Electronics America

Specifications of QB-179F124-T38MC

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
1.2
Emulation memory capacity
Program execution
functions
Memory manipulation
Register manipulation
Disassemble function
Local variable view
Watch data view
Stack trace view
Break functions
Trace functions
Real-time RAM monitoring function
Time measurement
functions
Other functions
This section shows the QB-179F124 system specifications.
Note The number of breaks that can be set varies depending on the location where the break is set.
System Specifications
Parameter
Measurement clock
Measurement objects
Maximum measurement time
Number of timers for
measurement
Measurement results
Other
Internal ROM
Internal RAM
Real-time execution function
Non-real-time execution function Step In, Next Over, Slowmotion, Go & Go
Event break
Software break
Pre-execution break
Fail-safe break
Other
Trace data types
Trace modes
Trace functions
Memory capacity
Table 1-2. System Specifications
Preliminary User’s Manual U18586EJ1V0UM
CHAPTER 1
512 KB (MAX.)
61.75 KB (MAX.)
Go, Start from Here, Come Here, Restart, Return Out,
Ignore break points and Go
Available (initialize, copy, compare)
Available (general-purpose registers, control registers, SFRs)
Available
Local variables
Local variables, global variables, or else
Available
Execution: 8 points
Access: 8 points
2000 points
4 to 8 points
Non-map, write protect, SFR illegal access, stack overflow, or else
Forcible break, trace full break, trace delay break, timeout break,
timer overflow break
Program address, program data, access address, access data,
status, time tag
Unconditional trace, section trace, qualify trace, delay trigger trace
Non-stop, full stop, full break, delay trigger stop, delay trigger
break
128K frames
All internal RAM spaces
60 MHz
Start through end of program execution
Start event through end event
Approx. 40 hours and 43 minutes (Resolution: 17 ns)
Start through end of program execution: 1
Start event through end event: 2
Execution time (start through end of execution)
Maximum, minimum, average, total, pass count (between events)
Timer overflow break function, timeout break function
Command functions set in the console, mapping function, event
function, coverage function, snapshot function, DMM function,
power-off emulation function, pin mask function, flash self
programming emulation function
GENERAL
Note
Specification
11

Related parts for QB-179F124-T38MC