DLP-IO20 DLP Design Inc, DLP-IO20 Datasheet - Page 4

MODULE DATA-ACQUISITION 20-CH

DLP-IO20

Manufacturer Part Number
DLP-IO20
Description
MODULE DATA-ACQUISITION 20-CH
Manufacturer
DLP Design Inc
Type
Motor / Motion Controllers & Driversr
Datasheet

Specifications of DLP-IO20

Module/board Type
Data Acquisition, 20-Channel
Input Voltage
0 V to 5 V
Output Voltage
5 V
Board Size
91.5 mm x 48.3 mm x 23 mm
Interface Type
USB
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Product
Power Management Modules
Dimensions
91.5 mm x 48.3 mm x 23 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
USB
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
813-1027
DLP-IO20-G

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DLP-IO20
Manufacturer:
DLP Design
Quantity:
135
AN3
GND
AN12
AN10
AN8
AN9
AN11
AN13
RB6
RB7
AN0
AN1
AN2
GND
S2
C2
R2
Notes:
1. The analog input range is 0-5V. The maximum sample rate is 20Ksps. Refer to section 7 for
2. Digital outputs can sink or source 25mA, 90mA for all combined. Open drain outputs are
3. Relay contacts can support resistive loads of up to 4A @ 30 VDC, 0.6A @ 110 VDC, and 1 A
4. The DLP-IO20 uses a single package multi-device driver (ULN2003APW). If only one of the
Rev. 1.0 (January 2009)
more details.
implemented by making the IO pin an input. The maximum pull-up voltage is 5.3 volts.
@ 125 VAC. If this value is exceeded the DLP-IO20 can be damaged. The relay is set and
reset under software control. For a functional schematic of the relay connections refer to figure
8.
driver channels is being used it can provide a peak current of 300mA at a 100% duty cycle, but
if all three channels are being used they can only provide a peak current of 100mA each at a
Analog Input AN3. Input voltage range is zero to +5V. (see note 1) Digital I/O AN3,
Configurable as a digital Input, a digital output (5V), or an open drain output (5V
MAX pullup). (see note 2)
Ground
Analog Input AN12. Input voltage range is zero to +5V. (see note 1) Digital I/O
AN12, Configurable as a digital Input, a digital output (5V), or an open drain output
(5V MAX pullup). (see note 2)
Analog Input AN10. Input voltage range is zero to +5V. (see note 1) Digital I/O
AN10, Configurable as a digital Input, a digital output (5V), or an open drain output
(5V MAX pullup). (see note 2)
Analog Input AN8. Input voltage range is zero to +5V. (see note 1) Digital I/O AN8,
Configurable as a digital Input, a digital output (5V), or an open drain output (5V
MAX pullup). (see note 2)
Analog Input AN9. Input voltage range is zero to +5V. (see note 1) Digital I/O AN9,
Configurable as a digital Input, a digital output (5V), or an open drain output (5V
MAX pullup). (see note 2)
Analog Input AN11. Input voltage range is zero to +5V. (see note 1) Digital I/O
AN11, Configurable as a digital Input, a digital output (5V), or an open drain output
(5V MAX pullup). (see note 2)
Analog Input AN13. Input voltage range is zero to +5V. (see note 1) Digital I/O
AN13, Configurable as a digital Input, a digital output (5V), or an open drain output
(5V MAX pullup). (see note 2)
Digital I/O RB6, Configurable as a digital Input, a digital output (5V), or an open
drain output (5V MAX pullup). (see note 2)
Digital I/O RB7, Configurable as a digital Input, a digital output (5V), or an open
drain output (5V MAX pullup). (see note 2)
Analog Input AN0. Input voltage range is zero to +5V. (see note 1) Digital I/O AN0,
Configurable as a digital Input, a digital output (5V), or an open drain output (5V
MAX pullup). (see note 2)
Analog Input AN1. Input voltage range is zero to +5V. (see note 1) Digital I/O AN1,
Configurable as a digital Input, a digital output (5V), or an open drain output (5V
MAX pullup). (see note 2)
Analog Input AN2. Input voltage range is zero to +5V. (see note 1) Digital I/O AN2,
Configurable as a digital Input, a digital output (5V), or an open drain output (5V
MAX pullup). (see note 2)
Ground
Latching Relay 2 Set Contact (see note 3)
Latching Relay 2 Common Contact (see note 3)
Latching Relay 2 Reset Contact (see note 3)
4
© DLP Design, Inc.