SUPERPRO3000U-100(ROHS) Xeltek, SUPERPRO3000U-100(ROHS) Datasheet - Page 36

PROGRAMMER UNIV STANDALONE W/USB

SUPERPRO3000U-100(ROHS)

Manufacturer Part Number
SUPERPRO3000U-100(ROHS)
Description
PROGRAMMER UNIV STANDALONE W/USB
Manufacturer
Xeltek
Series
SuperPro 3000U-100r
Type
Universal, Stand Aloner

Specifications of SUPERPRO3000U-100(ROHS)

Contents
Programmer with 48-DIP Pin Socket, AC Adapter, PEP3000 Module, CD, USB Cable, Users Guide and Power Supply
For Use With/related Products
E/EPROM, FLASH, PLD, Micros and more listed on Device Sheet. 44,000+ Devices Supported.
For Use With
415-1029 - SOCKET ADAPTER FOR SDIP42415-1028 - SOCKET ADAPTER FOR TQFP32415-1027 - SOCKET ADAPTER FOR TSOP56415-1025 - SOCKET ADAPTER FOR SOIC20415-1024 - SOCKET ADAPTER FOR TSOP40415-1023 - SOCKET ADAPTER FOR SOP44415-1022 - SOCKET ADAPTER FOR TSOP56415-1019 - SOCKET ADAPTER FOR SOIC16/SOIC8415-1018 - SOCKET ADAPTER FOR SOIC28415-1015 - SOCKET ADAPTER FOR PLCC28415-1014 - SOCKET ADAPTER FOR PLCC20415-1013 - SOCKET ADAPTER FOR PLCC32415-1012 - EXPANDER 100P FOR SUPERPRO3000U415-1017 - SOCKET ADAPTER FOR PLCC44
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
415-1007
SUPERPRO 3000U-100
SUPERPRO 3000U-100(ROHS)
Auto Increment allows users to add related info (8 bytes default) into the device. After each successful
programming, the software auto changes the value by the specified increment mode.
Note: no auto Increment under the standalone mode.
AutoInc. Set
·Set Start Address
·Set End Address
·Set increment value with any number less than 10
The address here is referred to the buffer address. Start address must be larger than the end address.
Auto Increment: define overflow value, from start address; unit is byte (max Dec 255).
When does the increment cease and carry to next address?
While a value reaches the overflow, carrying to next address (+1), this address becomes the start value.
Binary: start value is 0; overflow value is 256
ASCII Decimal: start value is 30 (Hex 0); overflow value 39+1 (Hex more than 9)
ASCII Hex: start value is 30 (Hex 0), overflow value is 46+1 (Hex more than F) 9+1=A
User defines: BCD is default. Start value is 00 (Hex). Overflow value is 09+1 (Hex). If user defines, a
config file and source program (in the CD) is required. In the VC++ environment revise and create the
file ‘UserAuto.dll’, and use it to replace the same name file in the Bin directory.
For example, there are 64 chips. Their IDs are from 0001 to 0064, which are in the end address of 89C51
EPROM. User selects the mode of 4 bytes and Dec. The steps are listed as below:
Click Option> Auto Increment
Set Start to FFC and End to FFF
Set IncValue to 1
Set Format to ASCII Decimal
Go into Buffer Edit screen at ASCII zone. Change buffer as follows:
FFC: 30 FFD: 30 FFE: 30 FFF: 31
During the programming, Operation Info screen displays:
Current AutoIncrement Data=0001

Related parts for SUPERPRO3000U-100(ROHS)