AD9514/PCB Analog Devices Inc, AD9514/PCB Datasheet - Page 21

no-image

AD9514/PCB

Manufacturer Part Number
AD9514/PCB
Description
BOARD EVAL CLOCK 3CHAN 32LFCSP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD9514/PCB

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Table 13. S5, S6—OUT2 Divide or OUT1 Phase
S5
0
1/3
2/3
1
0
1/3
2/3
1
0
1/3
2/3
1
0
1/3
2/3
1
1
Table 14. S7, S8—OUT1 Divide or OUT2 Phase
S7
0
1/3
2/3
1
0
1/3
2/3
1
0
1/3
2/3
1
0
1/3
2/3
1
1
Duty cycle is the clock signal high time divided by the total period.
Duty cycle is the clock signal high time divided by the total period.
S8
0
0
0
0
1/3
1/3
1/3
1/3
2/3
2/3
2/3
2/3
1
1
1
1
S6
0
0
0
0
1/3
1/3
1/3
1/3
2/3
2/3
2/3
2/3
1
1
1
1
S2 ≠ 1
OUT1
Divide (Duty Cycle
1
4 (50%)
18 (50%)
32 (50%)
2 (50%)
3 (33%)
5 (40%)
6 (50%)
8 (50%)
9 (44%)
10 (50%)
12 (50%)
15 (47%)
16 (50%)
24 (50%)
30 (50%)
S2 ≠ 0
OUT2
Divide (Duty Cycle
1
2 (50%)
3 (33%)
4 (50%)
5 (40%)
6 (50%)
8 (50%)
9 (44%)
10 (50%)
12 (50%)
15 (47%)
16 (50%)
18 (50%)
24 (50%)
30 (50%)
32 (50%)
1
)
1
)
OUT2
Phase
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
S2 = 1 and S0 ≠ 0
S2 = 0
OUT1
Phase
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Rev. 0 | Page 21 of 28
Table 15. S9, S10—OUT0 Divide or OUT2 Divide
S9
0
1/3
2/3
1
0
1/3
2/3
1
0
1/3
2/3
1
0
1/3
2/3
1
1
Duty cycle is the clock signal high time divided by the total period.
S10
0
0
0
0
1/3
1/3
1/3
1/3
2/3
2/3
2/3
2/3
1
1
1
1
S2 ≠ 2/3
OUT0
Divide (Duty Cycle
1
2 (50%)
3 (33%)
4 (50%)
5 (40%)
6 (50%)
8 (50%)
9 (44%)
10 (50%)
12 (50%)
15 (47%)
16 (50%)
18 (50%)
24 (50%)
30 (50%)
32 (50%)
1
)
S2 = 2/3
OUT2
Divide (Duty Cycle
7 (43%)
11 (45%)
13 (46%)
14 (50%)
17 (47%)
19 (47%)
20 (50%)
21 (48%)
22 (50%)
23 (48%)
25 (48%)
26 (50%)
27 (48%)
28 (50%)
29 (48%)
31 (48%)
AD9514
1
)

Related parts for AD9514/PCB