DEBUGGING COMMAND SET
GO
The GO command starts execution of code at the current program counter (PC) address, or at an
optional specified address.
The G, GO, and RUN commands are identical.
If you enter only one address, that address is the starting address. If you enter a second address,
the execution stops at that address. If you specify only one address, the execution continues until
you press a key, it arrives at a breakpoint, or an error occurs.
Syntax:
where:
Examples:
7-36
GO
GO
GO
G
RUN
300 371
<startaddr>
<endaddr>
[<startaddr> [<endaddr>]]
346
300
If you want to see the windows update with information during
execution of code, use the STEPFOR command.
Optional execution starting address. If the command does not have
a <startaddr> value, execution begins at the current PC value.
Optional execution ending address.
Begin code execution at the current PC value.
Begin code execution at address 346.
Begin code execution at address 300. End code execution
just before the instruction at address 371.
Begin code execution at address 300.
NOTE
Begin Program Execution