HS2378KCI01H

Manufacturer Part Number
HS2378KCI01H
Description
ON CHIP DEBUG EMULATOR
Manufacturer
Renesas Electronics America
Datasheets

Specifications of HS2378KCI01H

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
6. Memory Load Function
Note: The File Load function deletes the debugging information of the previously loaded
7. Line Assembly
8. Command Line Interface
When [Load...] is selected from the [Memory] menu, the Memory Load function can be used
although it takes time to download. It is recommended that the File Load function ([Load
Program...] selected from the [File] menu) is used to load the S-type file.
Array display
When array elements exceed 1000, elements from after 1000 will not be displayed.
Input radix
Regardless of the Radix setting, the default for line assembly input is decimal. Specify H’
or 0x as the radix for a hexadecimal input.
Batch file
To display the message “Not currently available” while executing a batch file, enter the
sleep command. Adjust the sleep time length which differs according to the operating
environment.
Overwrite file
In Command Line Interface, a file having the same name as the output file is overwritten
without asking the user.
File specification by commands
The current directory may be altered by file specifications in commands. Absolute paths
should be used to specify the files in a command file so that the current directory alteration
is not affected.
program. When other load modules are loaded after the program to be debugged has been
loaded, use the following sequence: Link the program to be debugged with the Sdebug
option and save the debugging information in another file. Load the debugging
information file after all the load modules have been loaded.
Example:
Example:
The function name is main.
main =
To display “Not currently available” during memory_fill
execution:
sleep d’3000
memory_fill 0 ffff 0
141