7.1
The performance measurement function has the following three commands:
7.1.1
Description:
Displays or initializes the performance measurement result.
Format:
pa [[<channel>] <display_mode>]
<channel> = channel <channel_number>
<display_mode> = mode <mode>
Table 7.1 PERFORMANCE_ANALYSIS Command Parameter
Parameter
<channel_
number>
<mode>
Notes: 1. The <channel> item can be set when the init keyword is set in the <mode> parameter.
Measurement result display/initialization command: PERFORMANCE_ANALYSIS (PA)
Performance condition cancellation command: PERFORMANCE_CLEAR (PC)
Performance condition set command: PERFORMANCE_SET (PS)
Section 7 Specific Commands of the SH7760 E10A
2.
3.
Performance Measurement Function
PERFORMANCE_ANALYSIS Command: PA
When <channel_number> is omitted at the initialization of the performance
measurement result, all performance measurement results are initialized.
When measurement channels 1 and 2 are not set or when the performance result is 0,
do not specify the rate1 or rate2 keyword for the <mode> parameter.
When the <display_mode> item is omitted, only the performance measurement results
are displayed.
Type
Numerical value
Keyword
Description
Sets a value of 1 or 2 as the channel number for the
performance measurement conditions.
Sets the display format of the performance measurement
result.
rate1 : Displays the ratio of the channel 1 result to that of
channel 2.
rate2 : Displays the ratio of the channel 2 result to that of
channel 1.
init : Initializes the performance measurement result.
Emulator