EVAL-ADT7475EB ON Semiconductor, EVAL-ADT7475EB Datasheet - Page 50

no-image

EVAL-ADT7475EB

Manufacturer Part Number
EVAL-ADT7475EB
Description
BOARD EVALUATION FOR ADT7475
Manufacturer
ON Semiconductor
Series
dBCool®r
Type
Temperature Sensorr
Datasheet

Specifications of EVAL-ADT7475EB

Contents
Evaluation Board
For Use With/related Products
ADT7475
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
1. This register becomes read−only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Table 30. Register 0x62 — Enhanced Acoustics Register 1 (Power−On Default = 0x00)
Bit No.
[2:0]
[3]
[4]
[5]
[6]
[7]
Mnemonic
ACOU1
SYNC
MIN1
MIN2
MIN3
EN1
(Note 1)
R/W
R/W
R/W
R/W
R/W
R/W
R/W
When Bit 7 of Configuration Register 6 (0x10) is 0
Time Slot Increase
When Bit 7 of Configuration Register 6 (0x10) is 1
Time Slot Increase
Assuming that PWMx is associated with the Remote 1 temperature channel, these bits define
the maximum rate of change of the PWMx output for Remote 1 temperature related changes.
Instead of the fan speed jumping instantaneously to its newly determined speed, it ramps
gracefully at the rate determined by these bits. This feature ultimately enhances the acoustics
of the fan.
000 = 1
001 = 2
010 = 3
011 = 4
100 = 8
101 = 12
110 = 24
111 = 48
000 = 1
001 = 2
010 = 3
011 = 4
100 = 8
101 = 12
110 = 24
111 = 48
When this bit is 1, smoothing is enabled on the Remote 1 temperature channel.
SYNC = 1 synchronizes fan speed measurements on TACH2, TACH3, and TACH4 to PWM3.
This allows up to three fans to be driven from PWM3 output and their speeds to be measured.
SYNC = 0 synchronizes only TACH3 and TACH4 to PWM3 output.
When the ADT7475 is in automatic fan control mode, this bit defines whether PWM1 is off
(0% duty cycle) or at PWM1 minimum duty cycle when the controlling temperature is below its
T
When the ADT7475 is in automatic fan speed control mode, this bit defines whether PWM2 is
off (0% duty cycle) or at PWM2 minimum duty cycle when the controlling temperature is below
its T
When the ADT7475 is in automatic fan speed control mode, this bit defines whether PWM3 is
off (0% duty cycle) or at PWM3 minimum duty cycle when the controlling temperature is below
its T
MIN
0 = 0% duty cycle below T
1 = PWM1 minimum duty cycle below T
0 = 0% duty cycle below T
1 = PWM 2 minimum duty cycle below T
0 = 0% duty cycle below T
1 = PWM3 minimum duty cycle below T
MIN
MIN
– hysteresis value.
– hysteresis value.
– hysteresis value.
http://onsemi.com
50
MIN
MIN
MIN
– hysteresis.
– hysteresis.
– hysteresis.
Time for 0% to 100%
Time for 0% to 100%
37.5 sec
18.8 sec
12.5 sec
7.5 sec
4.7 sec
3.1 sec
1.6 sec
0.8 sec
52.2 sec
26.1 sec
17.4 sec
10.4 sec
6.5 sec
4.4 sec
2.2 sec
1.1 sec
Description
MIN
MIN
MIN
– hysteresis.
– hysteresis.
– hysteresis.