Y92H-7 Omron, Y92H-7 Datasheet
Y92H-7
Specifications of Y92H-7
Related parts for Y92H-7
Y92H-7 Summary of contents
Page 1
... H3CR-F-300 48-125DC H3CR-F8N 100-240AC H3CR-FN-300 100-240AC H3CR-F8N 24AC/DC H3CR-FN-300 24AC/DC H3CR-F8N 12DC H3CR-FN-300 12DC H3CR-F8N 48-125DC H3CR-FN-300 48-125DC (c)Copyright OMRON Corporation 2007 All Rights Reserved. 24 VAC/VDC 12 VDC 1 300 h models 11-pin models 8-pin models H3CR-F8-300 100-240AC H3CR-F8-300 24AC/DC H3CR-F8-300 12DC H3CR-F8-300 48-125DC ...
Page 2
... Y92F-73 Y92F-74 PFP-50N PFP-100N PFP-100N2 PFP-M PFP-S Y92A-48B P2CF-08 P2CF-08-E P2CF-11 P2CF-11-E P3G-08 P3G-08 with Y92A-48G (See note 1) P3GA-11 P3GA-11 with Y92A-48G (See note 1) Y92H-7 Y92H-8 H3CR-F8 H3CR-FN Flicker ON start 8-pin 11-pin ×10 s (10 sec) min (min) 1 0. 120 1 300 × ...
Page 3
... EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4- contact discharge (level air discharge (level 3) IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level (0. MHz) (level 3) IEC61000-4- power-line (level I/O signal-line (level 4) IEC61000-4- line to line (level line to ground (level 3) (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-F 3 ...
Page 4
... OFF indicator detection circuit Indicator circuit ROM RAM Clock One-chip microcomputer H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300 Power supply Note: Leave terminals 5, 6, and 7 open. Do not use them as relay terminals. (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-F Output circuit Time range/unit selectors (+)(~) 4 ...
Page 5
... For ON-time setting OFF-time setting knob (with green pointer) For OFF-time setting ON-time unit display window ON-time unit selector (select one from sec min, and hrs, or from min, hrs, and 10 h) (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-F 0.1 s min OFF OFF ...
Page 6
... P3G-08/P3GA-11 81.5 17.4 80 H3CR-F8 H3CR-F8N 90.0 H3CR-F H3CR-FN P3GA-11 Y92F-30 (When * Y92A-48G 2.3 P2CF-08 mounted) P2CF-08-E (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-F 66.6 52.3 0.7 6 44.8 × 44.8 11 pins 66.6 0.7 5.7 52.3 6 44.8 × 44.8 8 pins 81.5 17.4 75 ...
Page 7
... Supply voltage 100 to 120 VAC H3CR-G8L 100-120AC 200 to 240 VAC H3CR-G8L 200-240AC 100 to 120 VAC H3CR-G8EL 100-120AC 200 to 240 VAC H3CR-G8EL 200-240AC (c)Copyright OMRON Corporation 2007 All Rights Reserved. 5. Supply Voltage 100-120AC: 100 to 120 VAC 200-240AC: 200 to 240 VAC 8-pin models 7 ...
Page 8
... P2CF-08 P2CF-08-E P3G-08 P3G-08 with Y92A-48G (See note 1) Y92S-27 Y92S-28 Y92P-48GL Y92P-48GB Y92P-48GM Y92H-1 Y92H-2 H3CR-G8L Star-delta timer with instantaneous output Time-limit: Instantaneous: SPST-NO (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-G Models H3CR-G8EL SPST-NO (star operation circuit) SPST-NO (delta operation circuit) ...
Page 9
... EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4-2: IEC61000-4-4: IEC61000-4-5: (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR contact discharge (level air discharge (level 3) IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level (0. MHz) (level power-line (level I/O signal-line (level 4) ...
Page 10
... Star Star-delta Star-delta operation transfer time transfer time time counting oscillation counting circuit circuit circuit (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-G Star operation Output circuit Delta operation Star operation indicator Indicator circuit Delta operation indicator Star operation ...
Page 11
... OFF ON OFF t1 ON OFF ON OFF Lit Not lit Lit Not lit Star-delta transfer time display window (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-G Star Delta operation operation contact contact them as relay terminals. 0.5 s min. t2 Time unit display (sec is fixed) Time setting knob (for setting ...
Page 12
... Time setting ring Panel cover Dimensions with Back Connecting Socket P3G- Y92F-30 * 2.3 (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-G 0.7 44.8 × 44.8 8 pins 92.9 86.4 H3CR- G8@L P3G-08 (When Y92A-48G mounted) 12 ...
Page 13
... H3CR-HRL 200-240AC M H3CR-HRL 24AC/DC M H3CR-HRL 48DC M H3CR-HRL 100-125DC M H3CR-H8RL 100-120AC S --- H3CR-H8RL 200-240AC S H3CR-H8RL 24AC/DC S H3CR-H8RL 48DC S H3CR-H8RL 100-125DC S Time range Supply voltage (c)Copyright OMRON Corporation 2007 All Rights Reserved. 6. Time Range min M-series 11-pin models 8-pin models H3CR-H8L 100-120AC M H3CR-H8L 200-240AC M ...
Page 14
... PFP-S Y92A-48B P2CF-08 P2CF-08-E P2CF-11 P2CF-11-E P3G-08 P3G-08 with Y92A-48G (See note 1) P3GA-11 P3GA-11 with Y92A-48G (See note 1) Y92H-1 Y92H-2 H3CR-H8L H3CR-H8RL Instantaneous operation/Time-limit reset/Forced reset No-voltage Relay output (SPDT) S-series s (sec) (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-H Models ...
Page 15
... EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4-2: IEC61000-4-4: IEC61000-4-5: (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR contact discharge (level air discharge (level 3) IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level (0. MHz) (level power-line (level I/O signal-line (level 4) ...
Page 16
... VDC for H3CR-H8RL (failure level: P). Time range/ unit selector Oscillation Counting Output circuit circuit circuit Indicator circuit Time range/ unit selector Oscillation Counting Output circuit circuit circuit Indicator circuit Input circuit (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-H Output indicator Output indicator 16 ...
Page 17
... With Reset Input (H3CR-HRL) Reset input Power supply Note: Leave terminal 6 open. Do not use them as relay terminals. http://www.ia.omron.com/ With Reset Input (H3CR-H8RL) Reset input Power supply Note: Leave terminal 3 open. Do not use them as relay terminals. (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-H 17 ...
Page 18
... Output (8 − 5) Lit Output indicator Not lit Rt ON Power (See note) OFF 0.05 s min. Reset input Output (1 − 3) Output (1 − 4) Output (11 − 9) Output (11 − 8) Lit Output indicator Not lit (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR 0.05 s min 0.05 s min. 18 ...
Page 19
... P3G-08/P3GA-11 92.9 15 86.4 H3CR-HRL 109.9 H3CR- H8@L P3G-08 Y92F-30 * P2CF-11 2.3 P2CF-11-E (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR-H Time setting knob (for setting power OFF-delay time) 78.0 0.7 44.8 × 44.8 8 pins 78.0 0.7 44.8 × 44.8 11 pins 92 ...
Page 20
... If the H3CR-H is dropped or experiences some other kind of shock, because a latching relay is used for output, contacts may be reversed or go into a neutral state. If the H3CR-H is dropped, reconfirm correct operation. Short-circuit current *: H3CR-H8RL (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3CR min min min. 20 ...
Page 21
... Normal operation may not be possible in locations subject to sulfidizing gas, such as in sewer systems or waste incinerators. OMRON does not market any Timers or other control devices for operation in atmospheres containing sulfidizing gas. Seal the Timer so that sulfidizing gas will not enter it. If sealing is not possible, OMRON does provide special Timers with improved resistance to sulfidizing gas ...
Page 22
... T X • Be sure that only a qualified worker (e.g., an electrical engineer) performs electrical work for the Timer. Incandescent lamp load times the rated current Mercury light loads times the rated load (c)Copyright OMRON Corporation 2007 All Rights Reserved. T Auxiliary relay (e.g., MY Relays) ...
Page 23
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...