R99-11 Omron, R99-11 Datasheet
R99-11
Specifications of R99-11
R9911
R9911NC
Z2000
Related parts for R99-11
R99-11 Summary of contents
Page 1
... Solid State Relays G3NA Wide Lineup of General-purpose Solid State Relays with Applicable Loads • AC Output Relays with 75-A and 90-A output currents have been added to the G3NA Series. • All models feature the same compact dimensions to provide a uniform mounting pitch. • Built-in varistor effectively absorbs external surges. ...
Page 2
Ordering Information ■ List of Models Isolation Zero cross Indicator function Phototriac Coupler Yes Yes (Yellow) Photocoupler Phototriac Coupler Photocoupler Phototriac Coupler Photocoupler Phototriac Coupler Photocoupler Phototriac Coupler Photocoupler Phototriac Coupler Photocoupler Yes --- * The standard models are certified ...
Page 3
... Y92B-P250 G3NA-450B(-2) Y92B-P250NF G3NA-275B-UTU(-2), G3NA-290B-UTU(-2), (See note.) G3NA-475B-UTU(-2), G3NA-490B-UTU(-2) Note: The Y92B-P250NF is scheduled for release on May 1, 2004. Mounting Bracket Model Applicable SSR R99-11 G3NA-240B, G3NA-440B(-2) Low-cost Models Model Applicable SSR Y92B-A100 G3NA-205B, G3NA-210B, G3NA-D210B, G3NA-220B, G3NA-410B, G3NA-420B Y92B-A150N G3NA-240B(-2), G3NA-440B(-2) Y92B-A250 ...
Page 4
... VAC 180 to 528 VAC (at 40°C) G3NA-490B-UTU(-2) Note: 1. The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data on page 6. 2. When an OMRON Heat Sink (refer to Options heat sink of the specified size is used. Operating Impedance voltage (See note 1 ...
Page 5
Characteristics Item G3NA- G3NA- G3NA- 205B 210B 220B Operate time 1/2 of load power source cycle + 1 ms max. (DC input) 3/2 of load power source cycle + 1 ms max. (AC input) Release time 1/2 of load ...
Page 6
Engineering Data Load Current vs. Ambient Temperature G3NA-205B With standard heat sink (Y92B-A100 or Y92B-N50) or aluminum plate measuring t3 Without heat sink Ambient temperature (°C) G3NA-240B 50 ...
Page 7
... Y92B-N100 1.99 Y92B-N150 0.45 Y92B-A100 0.45 Y92B-A150N Y92B-A250 Y92B-P250NF 2.62 Note: When using a commercially available heat sink, use one with a thermal resistance equal to or less that the OMRON Heat Sink. G3NA G3NA-240B G3NA-440B(-2)/-450B(-2) 400 300 200 100 0 500 1,000 5,000 ...
Page 8
... Dimensions ■ Relays Note: All units are in millimeters unless otherwise indicated. G3NA-205B, G3NA-210B, G3NA-220B, G3NA-410B, G3NA-420B 58 max. 47.5 44 G3NA-240B, G3NA-440B(-2) 58 min. 47.5 44 G3NA-D210B Note: The load can be connected to either the positive or negative side. 58 max. 47.5 44 G3NA-275B-UTU(-2), G3NA-475B-UTU(-2), G3NA-290B-UTU(-2), G3NA-490B-UTU(-2) 58 max. ...
Page 9
... Track. R99-12 FOR G3NA (for the G3NA and G3NE) 30 Two, M4 mounting 44 holes for the G3NE Mounting Bracket R99-11 (for the G3NA-240B, G3NA-440B(-2)) Use Mounting Bracket R99-11 so that the G3NA-240B/-440B can be mounted with the same pitch as that of the G3N-240B 12 Heat Sinks Y92B-N50 Heat Sink (for the G3NA-205B, G3NA-210B, G3NA-D210B, G3NA-410B, G3NE-210T(L)) For surface mounting, a 30% derating of the load current is required (from the Load Current vs ...
Page 10
Y92B-N100 Heat Sink (for the G3NA-220B, G3NA-420B, G3NE-220T(L)) For surface mounting, a 30% derating of the load current is required (from the Load Current vs. Ambient Temperature graphs). The orientation indicated by the external dimensions is not the correct mounting ...
Page 11
Y92B-P250 Two, M4 Four, M4 Depth 10 47.6 Four, R2.5 130.5 max. Y92B-A100 Heat Sink (for the G3NA-205B, G3NA-210B, Y92B-A150N Heat Sink G3NA-220B, (for the G3NA-240B, G3NA-410B, G3NA-440B(-2)) G3NA-420B, G3NA-D210B) Three, M4 holes Two, M4 holes R2.2 47.6 50±0.1 100 ...
Page 12
... Precautions for Safe Use Although OMRON continuously strives to improve the quality and reliability of our relays, the G3NA contains semiconductors, which are generally prone to occasional malfunction and failure. ...
Page 13
Operating and Storage Locations Do not use or store the G3NA in the following locations. Doing so may result in damage, malfunction, or deterioration of performance characteristics. • Do not use or store in locations subject to direct sunlight. • ...
Page 14
... Fan for replacement. • The recommended tightening torque for the Fan is 0.44 N⋅m. • Terminals equivalent to Faston #110 are used for the Fan power supply terminals. • Refer to the following table for the OMRON Fan power supply plug cables (order separately). Cable UL certified ...
Page 15
Preventing Overheating with a High- capacity Heat Sink (Y92B-P250NF) • When the High-capacity Heat Sink is used, high-capacity switching requires forced cooling with a fan. Connect the Fan to a power supply according to ...
Page 16
... Tighten the G3NA terminal screws properly. If the screws are not tight, the G3NA will be damaged by heat generated when the power is ON. Perform wiring using the specified tightening torque. 3. Handling Relays Do not mount the G3NA when your hands are oily or dirty, e.g., with metal powder. These may cause G3NA failure. ...
Page 17
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...