G79-Y100C Omron, G79-Y100C Datasheet - Page 3

no-image

G79-Y100C

Manufacturer Part Number
G79-Y100C
Description
CABLE HIGH DENSITY I/O 1M PLC
Manufacturer
Omron
Datasheet

Specifications of G79-Y100C

Accessory Type
Cable
For Use With/related Products
I/O Boards and PLC Modules
Color
-
Other names
G79Y100C
Q2101947A
G70D
Specifications
3 RATINGS
The following values apply to the G6D Relay mounted to the
G70D and do not apply to the G6D Relay itself before it is
mounted.
Electromechanical Relay (G6D) Specifications
Coil Ratings
Note: 1. The must operate voltage is 75% max. of the rated
Contact Ratings
Note: 1. This value is for when the maximum 8 points are ON.
Rated voltage
Rated current
Coil resistance
Must operate voltage
Release voltage
Max. allowable voltage
Power consumption
Load
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching capacity
Error rate (level p)
(reference value)
(see note 2)
Life expectancy
2. Rated current and coil resistance were measured at a
3. Operating characteristics were measured at a coil tem-
4. The maximum allowable voltage is the maximum value
5. The rated current includes the current consumption of
2. This value is for a switching frequency of 120 times per
voltage if the Relay is mounted upside down.
coil temperature of 23EC (73.4EF) with a tolerance of
perature of 23EC (73.4EF).
of the allowable voltage range for the relay coil operat-
ing power supply. There is no continuous allowance.
the operation indicator.
minute.
10%.
24 VDC
10.5 mA
2,880
70% max. of rated voltage
10% min. of rated voltage
130% of rated voltage
Approx. 200 mW
Resistive load (cos = 1)
3 A at 250 VAC, 3 A at 30 VDC
5 A (See Note 1)
250 VAC, 30 VDC
5 A
1,250 VA, 150 W
5 VDC, 1 mA
Electrical: 100,000 operations
min. (under and at the rated
load at 1,800 operations/hr)
Mechanical: 20,000,000
operations min. (at 18,000
operations/hr)
Power MOSFET Relay (G3DZ) Specifications
The following values apply to the G3DZ Relay mounted to the
G70D and do not apply to the G3DZ Relay itself before it is
mounted.
Input Ratings
Note: The rated current includes the current consumption of the
Output Ratings
Rated voltage
Operating voltage
Voltage level
Input impedance
Rated current
Load voltage
Load current
Inrush current
operation indicator.
3 to 264 VAC, 3 to 125 VDC
100 A to 0.3 A
6 A (10 ms)
Must operate
Must release
24 VDC
19.2 to 28.8 VDC
19.2 VDC max.
1 VDC min.
4 k
8.2 mA 20%
20%
G70D
3

Related parts for G79-Y100C