70G-OAC5A Grayhill Inc, 70G-OAC5A Datasheet

I/O MODULE 240VAC 3.5A W/FUSE

70G-OAC5A

Manufacturer Part Number
70G-OAC5A
Description
I/O MODULE 240VAC 3.5A W/FUSE
Manufacturer
Grayhill Inc
Series
70r
Type
ACr
Datasheet

Specifications of 70G-OAC5A

Turn Off Time
8.33ms
Color
Black
Style
G5
Voltage - Input
5VDC (4 ~ 6VDC)
Current - Input
20mA
Voltage - Output
24 ~ 280VAC (240VAC Nom)
Current - Output
0.03 ~ 3.5A
Turn On Time
8.33ms
Features
Hold Down Screw, Fused, Status LED(s)
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Load Current Rms Min
30mA
Peak Surge Current
80A
No. Of Analog Outputs
1
Load Current Rms Max
3.5A
Operating Voltage Max
220VAC
Brand/series
G5 Series
Connection To Host
Board Mount
Current, Input
20 mA
Current, Leakage
4 mA (RMS)
Module Type
Digital
Number Of Channels
1
Output
24 to 280 VAC
Output Type
Analog
Output, Range
24 to 280 VAC
Power Dissipation
1.0 W⁄A (Typ.)
Primary Type
Control
Resistance, Input
100 Ohms
Resistance, Insulation
100 Megohms (Min.) @ 500 VDC
Special Features
Optical Isolation
Standards
UL Listed, CSA Certified, and CE Marking
Temperature, Operating
-40 to +100 °C
Time, Turn-off
8.33 ms (Max.)
Time, Turn-on
8.33 ms (Max.)
Voltage, Isolation
4000 VAC
Voltage, Operating
240 VAC
Voltage, Supply
5 VDC
Contact Configuration
SPST-NO
No. Of Analog Inputs
1
No. Of Outputs
1
Rohs Compliant
No
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Lead free by exemption / RoHS compliant by exemption
Other names
GH3038
FEATURES
• Transient Protection: Meets the
• SPST, Normally Open
• Zero Crossing Turn-On
• UL, CSA, CE, TÜV Certified
• Optical Isolation
• OpenLine
• Built-in Status LED
• Lifetime Warranty
DIMENSIONS
For complete dimensional drawings, see pages
L-4 or L-5.
FUSES
G5 Fuses are 5 Amp Littelfuse part number
217005 or equivalent. OpenLine
3.15 Amp Littelfuse part number 2173.15.
SPECIFICATIONS: By Package Style
CIRCUITRY
1
2
3
4
5
6
7
I/O
6
requirements of IEEE 472, “Surge
Withstanding Capability Test”
Provide Replaceable 5x20 mm
Glass Fuses
Package Style
Specifications
Load Current Range
Maximum 1 Cycle Surge
Maximum Turn-On-Time (60 Hz)
Maximum Turn-Off Time (60 Hz)
Static dv/dt
Typ. Power Dissipation
Isolation Voltage
Vibration
Mechanical Shock
Storage Temp. Range
Operating Temp. Range
Warranty
See Figure 1 for derating.
Maximum 10 cycle surge is 50% of 1 cycle surge. Application of maximum surge may not be repeated until module temperature has returned
to its steady state value.
Except 70-OAC5A5 which is 200 µSec and 70-OAC5A-11, 70M-OAC5A-11, and 70G-OAC5A-11 which are 100 µSec.
Field to logic and channel-to-channel if Grayhill racks are used.
MIL-STD-202, Method 204, 20 , 10-2000 Hz or IEC68-2-6, 0.15 mm/sec
MIL-STD-202, Method 213, Condition F, 1500G or IEC68-2-27, 11 mS, 15g.
Except part numbers with -L suffix which have a dv/dt rating of 200 V/µSec.
Fuse and status LED in G5 and OpenLine modules only.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
5
DC CONTROL
+
VAC
7
®
and G5 Modules
LOAD
LOAD
4
6
Standard, Mini, G5
1
1
2
3
4
SNUBBER
AC Output Modules
2
Rx
TRIGGER
CIRCUIT
®
fuses are
3
V/µsec
A rms
A rms
V rms
Units
mSec
mSec
W/A
°C
°C
4
3
2
1
CH. A CONTROL
CH. B CONTROL
-40˚
STANDARD, G5 PACKAGES
MINIATURE PACKAGE
OPENLINE PACKAGE/CH
MODULE ID
-20˚
GND
MIL-STD-202
MIL-STD-202
Vcc
AMBIENT TEMPERATURE (˚C)
0.03 to 3.5
-40 to 125
-40 to 100
Std (70-)
Lifetime
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
0
3000
4000
8.33
8.33
5
6
7
1.0
80
Figure 1
2.15K
20˚
A
B
40˚
2
, 10-150 Hz.
TYPICAL WIRING FOR MODULE 0
60˚
CHANNEL B
CHANNEL A
ISOLATION
ISOLATION
OPTICAL
OPTICAL
MIL-STD-202
MIL-STD-202
Mini (70M-)
0.03 to 3.0
-40 to 125
-40 to 100
Lifetime
MODULE
80˚
OpenLine
3000
4000
8.33
8.33
1.0
80
70L-OAC
100˚
Maximum Current Versus
Ambient Temperature
The chart indicates continuous current to limit
the junction temperatures to 100°C. Information
is based on steady state heat transfer in a 2
cubic foot sealed enclosure.
®
SNUBBER
SNUBBER
MIL-STD-202
MIL-STD-202
G5 (70G-)
0.03 to 3.5
-40 to 125
-40 to 100
Lifetime
3000
4000
70G-OAC
8.33
8.33
1.0
80
1
2
3
4
RACK
BASE
OR
1
2
3
4
70-OAC
0.03 to 2.0/CH
LOAD
LOAD
IEC68-2-27
TERMINAL
BLOCK #
OL (70L-)
IEC68-2-6
-40 to 100
-40 to 85
Lifetime
I/O MODULE
PIN #
3000
2500
8.33
8.33
1.0
30
70M-OAC

Related parts for 70G-OAC5A

70G-OAC5A Summary of contents

Page 1

... Maximum 10 cycle surge is 50 cycle surge. Application of maximum surge may not be repeated until module temperature has returned to its steady state value. 3 Except 70-OAC5A5 which is 200 µSec and 70-OAC5A-11, 70M-OAC5A-11, and 70G-OAC5A-11 which are 100 µSec. 4 Field to logic and channel-to-channel if Grayhill racks are used. ...

Page 2

... Vdc 5 5 Vdc 2.5-10 2.5-10 10- 240 240 1800 Vdc 1 1 Vdc -5 -5 70G-OAC5 70G-OAC5A 70G-OAC15 70G-OAC5-L 70G-OAC5A-L 70G-OAC15-L Units Vac 120 240 Vac 24-140 24-280 24-140 Volts 400 600 mA, rms 2 4 Vdc 5 5 Vdc 4-6 4 100 100 ...