G2R-2-SND DC24(S) Omron, G2R-2-SND DC24(S) Datasheet - Page 6

RELAY PWR DPDT 5A 24VDC PLG

G2R-2-SND DC24(S)

Manufacturer Part Number
G2R-2-SND DC24(S)
Description
RELAY PWR DPDT 5A 24VDC PLG
Manufacturer
Omron
Series
G2RSr
Datasheets

Specifications of G2R-2-SND DC24(S)

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
5A
Switching Voltage
380VAC, 125VDC - Max
Coil Type
Standard
Coil Current
21.6mA
Coil Voltage
24VDC
Turn On Voltage (max)
16.8 VDC
Turn Off Voltage (min)
3.6 VDC
Mounting Type
Socket
Termination Style
Socketable
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
5A @ 250VAC
Control On Voltage (max)
16.8 VDC
Control Off Voltage (min)
3.6 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G2R-2-SNDDC24(S)
G2R-2-SNDDC24(S)
G2R2SNDDC24S
Z2866
G2R
Double-winding Latching Relays
Note:
I
UL 508 (File No. E41643)
6
Contact resistance
Set time
Reset time
Min. set/reset signal width
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
G2R-1
G2R-14
G2R-1-H
G2R-1-S
G2R-1-T
G2R-1A
G2R-1A4
G2R-1A-H
G2R-1A-S
G2R-1A-T
G2R-1-E
G2R-1A-E
G2R-2
G2R-24
G2R-2-H
G2R-2-S
G2R-2A
G2R-2A4
G2R-2A-H
G2R-2A-S
G2R-1A-ASI
Approved Standards
Values in the above table are the initial values.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted.
Model
Item
SPDT
SPST-NO
SPDT
SPST-NO
DPDT
DPST-NO
SPST-NO
30 m
20 ms max.
20 ms max.
30 ms max.
Mechanical:18,000 operations/hr
Electrical:
1,000 M
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts
of same pole;
1,000 VAC, 50/60 Hz for 1 min between set and
reset coil
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: Set: 500 m/s
Reset:
Mechanical: 10,000,000 operations min (at 18,000 operations/hr)
Electrical:
Operating: 40°C to 70°C (with no icing)
Operating: 5% to 85%
Approx. 17 g
Contact form
max.
min. (at 500 VDC)
1,800 operations/hr (under rated load)
100,000 operations min. (at 1,800 operations/hr under rated load)
100 m/s
2
1 pole
(approx. 10G)
2
3 to 110 VDC
3 to 240 VAC
(approx. 100G)
2
Coil ratings
(approx. 50G); 200m/s
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
16 A, 30 VDC (resistive, NO contact only)
16 A, 250 VAC (general use, NO contact only)
TV-3 (NO contact only); 1/3 hp, 120 VAC
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
10 A, 250 VAC (general use)
TV-5/TV-8 (NO contact only)
10 A, 30 VDC (resistive)
2
50 m
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts
of different poles
1,000 VAC, 50/60 Hz for 1 min between contacts
of same pole
1,000 VAC, 50/60 Hz for 1 min between set and
reset coil
(approx. 20G)
max.
Contact ratings
2 poles
G2R

Related parts for G2R-2-SND DC24(S)