LKS1AF-5V Panasonic Electric Works, LKS1AF-5V Datasheet - Page 3

RELAY PWR SPST-NO 5A 5V PC MNT

LKS1AF-5V

Manufacturer Part Number
LKS1AF-5V
Description
RELAY PWR SPST-NO 5A 5V PC MNT
Manufacturer
Panasonic Electric Works
Series
LK-Sr
Type
Power Relayr
Datasheet

Specifications of LKS1AF-5V

Relay Type
General Purpose
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
5A
Switching Voltage
277VAC
Coil Type
Standard
Coil Current
50mA
Coil Voltage
5VDC
Turn On Voltage (max)
3.5 VDC
Turn Off Voltage (min)
0.5 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
5A @ 277VAC
Control On Voltage (max)
3.5 VDC
Control Off Voltage (min)
0.5 VDC
Relay Construction
Non-Latching
Contact Arrangement
SPST-NO
Coil Voltage Dc
5V
Voltage Rating (vac)
277V
Dropout Volt (min)
0.5VDCV
Coil Resistance
100Ohm
Pick-up Voltage (max)
3.5VDC
Maximum Power Rating
1.385KVA
Operate Time
15ms
Contact Current Rating
5A
Contact Material
Ag
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Flux Resistant
Product Height (mm)
25mm
Product Depth (mm)
11mm
Product Length (mm)
24mm
Operating Temp Range
-40C to 70C
Pin Count
4
Mounting Style
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1268

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LKS1AF-5V
Manufacturer:
PANASONIC
Quantity:
12 000
4. Life curve
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: Room temperature
5-(1). Electrical life test
(5 A 277 V AC, resistive load)
Sample: LKS1aF-12V, 6 pcs.
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: 20 C
Circuit:
5-(2). Electrical life test
(UL lamp load test TV-5)
Tested sample: LKS1aF-12V, 6 pcs.
• Overload test
• Endurance test
Load: 7.5 A 120 V AC (60 Hz),
Inrush: 111 A
Operation frequency: 10 times/min
(ON: OFF = 1 s: 5 s)
No. of operations: 50 ope.
Load: 5A 120 V AC (60 Hz),
Inrush: 78 A
Operation frequency: 10 times/min
(ON: OFF = 1 s: 5 s)
No. of operations: 25,000 ope.
277V AC
100
10
1
0
1
Contact current, A
2
12V DC
250V AC resistive load
68 F
3
4
Contact
welding
detection
and Mis-
contacting
detection
circuit
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
5
Change of pick-up and drop-out voltage
Change of pick-up and drop-out voltage
12
10
12
10
8
6
4
2
0
8
6
4
2
0
0
0
Drop-out voltage
No. of operations, 10
Drop-out voltage
No. of operations, 10
Pick-up voltage
Pick-up voltage
5
4
4
2.5
10
Max.
x
Min.
Max.
x
Min.
Max.
x
Min.
Max.
x
Min.
Change of contact resistance
Change of contact resistance
50
45
40
35
30
25
20
15
10
50
45
40
35
30
25
20
15
10
5
0
5
0
0
0
No. of operations, 10
No. of operations, 10
5
4
4
LK-S
2.5
10
Max.
x
Min.
Max.
x
Min.

Related parts for LKS1AF-5V