HE2AN-DC24V Panasonic Electric Works, HE2AN-DC24V Datasheet

RELAY POWER 25A 24VDC PLUG-IN

HE2AN-DC24V

Manufacturer Part Number
HE2AN-DC24V
Description
RELAY POWER 25A 24VDC PLUG-IN
Manufacturer
Panasonic Electric Works
Series
HEr
Type
Power Relayr
Datasheets

Specifications of HE2AN-DC24V

Relay Type
General Purpose
Contact Form
DPST (2 Form A)
Contact Rating (current)
25A
Switching Voltage
277VAC
Coil Type
Standard
Coil Current
80mA
Coil Voltage
24VDC
Turn On Voltage (max)
16.8 VDC
Turn Off Voltage (min)
2.4 VDC
Mounting Type
Chassis Mount
Termination Style
Quick Connect - .250" (6.3mm)
Circuit
DPST (2 Form A)
Contact Rating @ Voltage
25A @ 277VAC
Control On Voltage (max)
16.8 VDC
Control Off Voltage (min)
2.4 VDC
Brand/series
HE Series
Current, Rating
25 A
Function
Power
Latch Type
Single Side Stable
Power, Rating
8310 VA
Standards
UL, CSA, VDE, TUV
Termination
Plug-In
Voltage, Control
24 VDC
Voltage, Rating
277 VAC
Relay Construction
Non-Latching
Contact Arrangement
DPST-NO
Coil Voltage Dc
24V
Voltage Rating (vdc)
30V
Voltage Rating (vac)
277V
Dropout Volt (min)
2.4VDCV
Coil Resistance
300Ohm
Pick-up Voltage (max)
16.8VDC
Maximum Power Rating
6.925KVA
Operate Time
30ms
Contact Current Rating
25A
Contact Material
Ag
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
46.2mm
Product Depth (mm)
33mm
Product Length (mm)
50mm
Operating Temp Range
-50C to 55C
Pin Count
6
Mounting Style
Plug-In
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1660

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HE2AN-DC24V
Manufacturer:
PANASONIC
Quantity:
12 000
CLASSIFICATION
PRE-TENSION AND KICK-OFF MECHANISM
1. Pre-tension mechanism
Before operation, the moving
spring is pre-tensioned by
being held down by a moving
plate. As a result, at the ON
moment, with little follow,
contact pressure is ensured
with low bounce.
Contact arrangement
Operating funciton
0
Type
1 Form A Plug-in type
Contact follow stroke
Direction of operation
HE relay
(with pre-tension)
Ordinary relay
(without pre-tension)
Pre-tension
PC board
1 Form A
Moving plate
1 Form A
At operation
FEATURES
1. Excellent resistance to contact
welding
Owing to the pre-tension and kick-off
mechanism, the 1 Form A passes TV-15
and the 2 Form A passes TV-10.
2. High-capacity and long life
3. Excellent surge resistance
Between contacts and coil, the surge
voltage is more than 10,000 V
(when surge waveform accords with
JEC-212-1981).
Contact
arrangement
Contact capacity
Electrical life
(at 20 cpm)
Mechanical life
(at 180 cpm)
Type
Insulation gap
Distance between contacts*
Breakdown
voltage
TV-15, 30 AMP (1 Form A)
Plug-in
Power Relay
2 Form A
Between open contacts
Between contact and coil
1 Form A type 2 Form A type
DC type: 10
30A
2. Kick-off mechanism
Even when contact welding
has occurred, at the moment of
return, the moving plate taps
the moving spring (kick-off)
and, in effect, works to tear the
weld apart, thus improving
resistance to welding.
Electrical life
TV rating
Single side stable
2 10
7
, AC type: 5 10
1 Form A
Moving plate
5
20A
TM
6
1 Form A and 2 Form A:
30 A 277 V AC, 10
30 A 250 V AC, 20
2 Form A
4. Compatible with all major safety
standards
UL, CSA, VDE and TÜV certified
TYPICAL APPLICATIONS
1. Office equipment
Copiers, package air conditioners,
automatic vending machines.
2. Industrial equipment
Machine tools, molding equipment,
wrapping machines, food processing
equipment, etc.
3. Home appliances
Air conditioners, microwave ovens,
televisions, stereo systems, water
heaters and air heating equipment.
Min. 3 mm
1 Form A
HE RELAYS
TV-15
Gap
Kick-off
HE 1 Form A, 2 Form A
Single side stable type
2, 000 Vrms for 1 min.
5, 000 Vrms for 1 min.
5
5
Min. 8 mm
1 Form A
Screw terminal
25 A 277 V AC, 10
20 A 250 V AC, 20
At return
PC board type:
Min. 2.5 mm
2 Form A
TV-10
VDE
2 Form A
HE
5
5

Related parts for HE2AN-DC24V

HE2AN-DC24V Summary of contents

Page 1

... At operation weld apart, thus improving resistance to welding. Moving plate Electrical life TV rating VDE HE RELAYS 4. Compatible with all major safety standards UL, CSA, VDE and TÜV certified TYPICAL APPLICATIONS 1. Office equipment Copiers, package air conditioners, automatic vending machines. ...

Page 2

... AC 200/240V AC 1 Form A Part No. HE1aN-P-DC6V HE1aN-P-DC12V HE1aN-P-DC24V HE1aN-P-DC48V HE1aN-P-DC100V HE1aN-P-DC110V 1 Form A 2 Form A Part No. Part No. HE1aN-DC6V HE2aN-DC6V HE1aN-DC12V HE2aN-DC12V HE1aN-DC24V HE2aN-DC24V HE1aN-DC48V HE2aN-DC48V HE1aN-DC100V HE2aN-DC100V HE1aN-DC110V HE2aN-DC110V HE1aN-AC12V HE2aN-AC12V HE1aN-AC24V HE2aN-AC24V HE1aN-AC48V HE2aN-AC48V HE1aN-AC100V HE2aN-AC100V HE1aN-AC200V HE2aN-AC200V 1 Form A 2 Form A Part No ...

Page 3

... DC 110V DC 1 Form A Part No. HE1aN-S-DC6V HE2aN-S-DC6V HE1aN-S-DC12V HE2aN-S-DC12V HE1aN-S-DC24V HE2aN-S-DC24V HE1aN-S-DC48V HE2aN-S-DC48V HE1aN-S-DC100V HE2aN-S-DC100V HE1aN-S-DC110V HE2aN-S-DC110V HE1aN-S-AC12V HE2aN-S-AC12V HE1aN-S-AC24V HE2aN-S-AC24V HE1aN-S-AC48V HE2aN-S-AC48V HE1aN-S-AC100V HE2aN-S-AC100V HE1aN-S-AC200V HE2aN-S-AC200V Drop-out voltage Nominal operating current ( 10%] ( 138mA 74mA 15%V or more of nominal voltage 39mA (Initial) 18 ...

Page 4

HE 2. Specifications Characteristics Item Arrangement Contact Initial contact resistance, max Contact material Nominal switching capacity (resistive load) Max. switching power Max. switching voltage Rating Max. switching current Nominal operating power Min. switching capacity (Reference value)* Insulation resistance (Initial) Between ...

Page 5

HE 2. Plug-in type 1 Form A 0.8 .031 2 Form A 0.8 .031 3. TM type External dimensions Single side stable type 1 Form A 47.6 1.874 36.4 1.433 1 4 4.5 .177 R.157 40 1.575 ...

Related keywords