SP4-DC12V Panasonic Electric Works, SP4-DC12V Datasheet - Page 7

RELAY POWER 10A 12VDC PLUG-IN

SP4-DC12V

Manufacturer Part Number
SP4-DC12V
Description
RELAY POWER 10A 12VDC PLUG-IN
Manufacturer
Panasonic Electric Works
Series
SPr
Type
Power Relayr
Datasheet

Specifications of SP4-DC12V

Relay Type
General Purpose
Contact Form
4PDT (4 Form C)
Contact Rating (current)
10A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
25mA
Coil Voltage
12VDC
Turn On Voltage (max)
8.4 VDC
Turn Off Voltage (min)
1.2 VDC
Mounting Type
Socket
Termination Style
Quick Connect - .187" (4.7mm)
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
10A @ 250VAC
Control On Voltage (max)
8.4 VDC
Control Off Voltage (min)
1.2 VDC
Relay Construction
Non-Latching
Contact Arrangement
4PDT
Coil Voltage Dc
12V
Voltage Rating (vdc)
30V
Voltage Rating (vac)
250V
Dropout Volt (min)
1.2VDCV
Coil Resistance
480Ohm
Pick-up Voltage (max)
8.4VDC
Maximum Power Rating
300W/2.5KVA
Operate Time
30ms
Contact Current Rating
10A
Contact Material
AgSnO2
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
22mm
Product Depth (mm)
25.6mm
Product Length (mm)
51mm
Operating Temp Range
-50C to 60C
Pin Count
14
Mounting Style
Plug-In
Package / Case
Dust Cover
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-2840
SP4-DC12V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SP4-DC12V
Manufacturer:
Matsushita
Quantity:
12 000
SP
Direct chassis mounting possible, and applicable to DIN rail.
DIMENSIONS
Mounting hole diagram
Use method
1. Both the SP relay 2 Form C and
4 Form C can be mounted to the
mounting slats.
2. Use the mounting slats either by
attaching them directly to the chassis, or
by mounting with a DIN rail.
(A) When attaching directly to chassis
Use two M3 screws.
For the mounting pitch, refer to the
specification diagram.
(B) When mounting on a DIN rail
Use a 35mm
(DIN46277).
The mounting method should be as
indicated in the diagram at right.
CAD Data
18.4
.724
Panel cutout
1.378inch
18.4
.724
2.252
57.2
Tolerance: 0.1
(mm inch)
2-3.2 dia. hole
2-.126 dia. hole
wide DIN rail
.984
23.2
.913
25
.004
The CAD data of the products with a
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Method for mounting on DIN rail
Fit into mounting
grooves.
Press
ACCESSORIES
Press relay in
Fit in
TYPES
CAD Data
Mounting board
To remove the
relay, press down
the mounting slats
so the claws move
to the outside.
Product name
Mounting
slat
DIN rail
Fig. 1
Fig. 2
Fig. 3
mark can be downloaded from: http://panasonic-electric-works.net/ac
(1) First fit the arc shaped claw of the
mounting slat into the DIN rail.
(2) Press on the side as shown in the
diagram below.
(3) Fit in the claw part on the opposite
side.
Precautions for use
When mounting to a DIN rail, use a
commercially available fastening bracket
if there is a need to stop sliding of the
mounting slat in the rail direction.
MOUNTING BOARD
SP RELAYS
Part No.
SP-MA

Related parts for SP4-DC12V